Special Section on Dimensional Metrology with Atomic Force Microscopy: Instruments and Applications

New developments at Physikalisch Technische Bundesanstalt in three-dimensional atomic force microscopy with tapping and torsion atomic force microscopy mode and vector approach probing strategy

[+] Author Affiliations
Gaoliang Dai, Wolfgang Häßler-Grohne, Dorothee Hüser, Helmut Wolff, Jens Fluegge, Harald Bosse

Physikalisch Technische Bundesanstalt, 38116 Braunschweig, Germany

J. Micro/Nanolith. MEMS MOEMS. 11(1), 011004 (Feb 29, 2012). doi:10.1117/1.JMM.11.1.011004
History: Received May 11, 2011; Revised October 19, 2011; Accepted October 25, 2011
Text Size: A A A

Abstract.  A new three-dimensional atomic force microscopy (3D-AFM) for true 3D measurements of nanostructures has been developed at Physikalisch Technische Bundesanstalt (PTB), the national metrology institute of Germany. In its configuration, two piezo actuators are applied to drive the AFM cantilever near its vertical and torsional resonant frequencies. In such a way, the AFM tip can probe the surface with a vertical and/or a lateral oscillation, offering high 3D probing sensitivity. For enhancing measurement flexibility as well as reducing tip wear, a vector approach probing (VAP) method is applied. The sample is measured point by point using this method. At each probing point, the tip is approached toward the surface in its normal direction until the desired tip-sample interaction is detected and is then immediately withdrawn from the surface. Preliminary experimental results show promising performance of the PTB system. The measurement of an IVPS 100 sample using a flared AFM tip showed a repeatability of its 3D profiles better than 1 nm (p-v). A single crystal critical dimension reference material having features with almost vertical sidewalls was also measured using a flared AFM tip. These results show that the feature has average left and right sidewall angles of 89.5 and 89.4, respectively. However, the nonuniformity of the feature width within the measurement window of 1 μm may be up to 10 nm. The standard deviation of the average middle CD values from 10 repeated measurements is 0.1 nm. In addition, an investigation of long-term measurement stability was performed on a PTB photomask. The results changed at a rate of about 0.00033 nm per line, which confirms the high measurement stability and the very low tip wear of the system.

© 2012 Society of Photo-Optical Instrumentation Engineers

Citation

Gaoliang Dai ; Wolfgang Häßler-Grohne ; Dorothee Hüser ; Helmut Wolff ; Jens Fluegge, et al.
"New developments at Physikalisch Technische Bundesanstalt in three-dimensional atomic force microscopy with tapping and torsion atomic force microscopy mode and vector approach probing strategy", J. Micro/Nanolith. MEMS MOEMS. 11(1), 011004 (Feb 29, 2012). ; http://dx.doi.org/10.1117/1.JMM.11.1.011004


Tables

Access This Article
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Article
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.