Presentation + Paper
17 September 2018 High-resolution DMD-FPM system based on ring pattern phase retrieval algorithm
Author Affiliations +
Abstract
We report an approach to enhance the resolution of the microscopy imaging by using the fourier ptychographic microscopy (FPM) method with a laser source and Spatial Light Modulator (SLM) to generate modulated sample illumination. The performance of the existed FPM system is limited by low illumination efficiency of the LED array. In our prototype setup, digital micromirror device (DMD) is introduced to replace the LED array as a reflective spatial light modulator and is placed at the front focal plane of the 4F system. A ring pattern sample illumination is generated by coding the micromirrors on the DMD, and converted to multi-angular illumination through the relay illumination system. A series of intensity sample images can be obtained by changing the size of the ring pattern and then used to reconstruct high resolution image through the ring pattern phase retrieval algorithm. Finally, our method is verified by an experiment using a resolution chart. The results also show that our method have higher reconstruction resolution and faster imaging speed.
Conference Presentation
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Xiao Tao, Jinlei Zhang, Youquan Liu, Chang Wang, Wentao Zhang, Chenning Tao, Shengqian Chang, and Zhenrong Zheng "High-resolution DMD-FPM system based on ring pattern phase retrieval algorithm", Proc. SPIE 10752, Applications of Digital Image Processing XLI, 107521K (17 September 2018); https://doi.org/10.1117/12.2319648
Lens.org Logo
CITATIONS
Cited by 2 patents.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Reconstruction algorithms

Digital micromirror devices

Imaging systems

Image resolution

Phase retrieval

Micromirrors

Objectives

Back to Top