This paper focuses on the calibration and verification of the DESIS (DLR Earth Sensing Imaging Spectrometer) detector for the VIS/NIR (VNIR) spectral range. DESIS is a hyperspectral Instrument for the international space station, developed from the German Aerospace Center (DLR) and operate by Teledyne Brown Engineering (TBE). TBE provides the MUSES platform, on which the DESIS instrument will be mounted. The primary goal of DESIS is to measure and analyse quantitative diagnostic parameters describing key processes on the Earth surface. The main components of the sensor, the detector and the focal plane, were examined and verified. This allows predictions about the future data quality. The verification and validation of components and the entire system is an important and challenging task. The verification of the detectors is necessary to describe the characteristics of the detector according to predetermined specifications. The quantities to be examined are e.g. the quantum efficiency, the linearity of the detector, the pixel response non-uniformity (PRNU) and the dark current noise. For this purpose, specially calibrated integrated spheres are used that allow traceability of the measured data. With these information, the future performance of the sensor can be estimated using simulations.
Conference Presentation
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Andreas Eckardt, David Krutz, Thomas Säuberlich, Holger Venus, and Ralf Reulke "Verification and calibration of the DESIS detector", Proc. SPIE 10768, Imaging Spectrometry XXII: Applications, Sensors, and Processing, 107680B (18 September 2018); https://doi.org/10.1117/12.2319303
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Quantum efficiency

Calibration

Photons

Signal detection

Signal to noise ratio

Electroluminescence

RELATED CONTENT

Acousto-optic imaging with a smart-pixels sensor
Proceedings of SPIE (March 13 2015)
A low-light camera SNR D* metric
Proceedings of SPIE (June 07 2024)
Streak tube dynamic range
Proceedings of SPIE (January 01 1992)
Design of the stressed Ge Ga far infrared array for...
Proceedings of SPIE (August 21 1998)
Deep fiber spectroscopy
Proceedings of SPIE (July 01 1990)

Back to Top