Paper
25 July 1989 Effects of Line Narrowing and Collimation on Excimer Radiation at 248nm
William N. Partlo, Chris A. Spence, William G. Oldham
Author Affiliations +
Abstract
The relevant characteristics of a 248 nm line-narrowed excimer laser have been measured. The laser's spectral width is 1.6 pm FWHM and its coherence length is 38 mm. The effects of this line narrowing on the optical components in illuminator systems have been studied. The results from several light pipe systems and a diffuser plate system are presented. The effects of external cavity collimation on the GCA-TROPEL BOLD illuminator are also presented.
© (1989) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
William N. Partlo, Chris A. Spence, and William G. Oldham "Effects of Line Narrowing and Collimation on Excimer Radiation at 248nm", Proc. SPIE 1088, Optical/Laser Microlithography II, (25 July 1989); https://doi.org/10.1117/12.953174