Paper
1 January 1992 New look at incoming pellicle inspection
Robert W. Murphy, James A. Reynolds
Author Affiliations +
Abstract
One of the most difficult steps in the photomask process is that of cleaning and pelliclizing a mask or reticle. This must be done in a way that guarantees zero particles in the pellicle volume at the time of pelliclization as well as throughout the life of the reticle. With the advent of 16 and 64 Megabit DRAM processing, the elimination of these particles becomes more important and more difficult. Considerable effort has been expended to perfect cleaning and inspection equipment used to clean the reticle before pelliclization and inspect it afterwards. The incoming pellicle, however, can be an equally large source of defects which can cause a reticle to fail, either in outgoing inspection or after many months of use. This paper deals with several aspects of incoming pellicle inspection. The inspection equipment and techniques used at Apex are described. Defect types are defined with photographs and drawings. The specification gap between the needs of the mask users and the capabilities of pellicle suppliers is discussed. Finally inspection yield data is presented with Pareto analysis showing the beneficial effect of incoming pellicle inspection.
© (1992) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Robert W. Murphy and James A. Reynolds "New look at incoming pellicle inspection", Proc. SPIE 1604, 11th Annual BACUS Symposium on Photomask Technology, (1 January 1992); https://doi.org/10.1117/12.56940
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Pellicles

Inspection

Particles

Reticles

Adhesives

Photomasks

Epoxies

RELATED CONTENT

Is mask repair economic?
Proceedings of SPIE (February 12 1997)
DUV pellicle quality assessment based on customer priorities
Proceedings of SPIE (December 18 1998)
Development of a new pellicle for use with the new...
Proceedings of SPIE (July 28 1997)
Mask defect reduction through automated pellicle mounting
Proceedings of SPIE (December 06 2004)
Advanced pelliclization techniques
Proceedings of SPIE (December 07 1994)

Back to Top