20 June 1995 X-ray study of a SODART flight telescope using the expanded beam x-ray optics beamline at the Daresbury synchrotron
Finn Erland Christensen, Allan Hornstrup, Peter K. Frederiksen, Salim Abdali, P. Grundsoe, Josef Polny, Niels J. Westergaard, Hans Ulrich Noergaard-Nielsen, Herbert W. Schnopper, C. Hall, R. Lewis
Author Affiliations +
Abstract
The on- and off-axis imaging properties of the first of two SODART flight telescopes have been studied using the expanded beam x-ray facility at the Daresbury synchrotron. From on- axis measurements the encircled power distribution and the point spread function at three energies 6.627 keV, 8.837 keV, and 11.046 keV have been measured using a one dimensional position sensitive detector. The data have been used to calculate the half power diameter (HPD) for three different SODART focal plane detectors, the high energy proportional counter (HEPC), the low energy proportional counter (LEPC) and the 19 element solid state array detector (SIXA). We found that the HPD decreases with increasing energy due to poorer figure error of the outermost mirrors. The HPD falls in the range from 2.3 to 3 arcmin for all detectors. Residual misalignment of the individual quadrants of the telescope was found to contribute to the HPD by approximately 10%. If 33% of the geometric telescope area near the edges of the quadrants are covered a reduction of 10% of the HPD can be obtained. On- and off-axis images generated from the one dimensional intensity distribution are presented. Finally the data have been used to calculate the variation of the effective area versus the off- axis angle.
© (1995) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Finn Erland Christensen, Allan Hornstrup, Peter K. Frederiksen, Salim Abdali, P. Grundsoe, Josef Polny, Niels J. Westergaard, Hans Ulrich Noergaard-Nielsen, Herbert W. Schnopper, C. Hall, and R. Lewis "X-ray study of a SODART flight telescope using the expanded beam x-ray optics beamline at the Daresbury synchrotron", Proc. SPIE 2515, X-Ray and Extreme Ultraviolet Optics, (20 June 1995); https://doi.org/10.1117/12.212612
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Telescopes

X-ray telescopes

Mirrors

Sensors

Space telescopes

X-rays

X-ray optics

RELATED CONTENT

Status of ART-XC / SRG instrument
Proceedings of SPIE (September 04 2015)
ART-XC / SRG overview
Proceedings of SPIE (July 06 2018)
X-Ray Spectrometer Spectrograph Telescope System
Proceedings of SPIE (August 09 1979)
X ray study of a test quadrant of the SODART...
Proceedings of SPIE (November 11 1994)
X-ray calibration of the SODART flight telescopes
Proceedings of SPIE (July 11 1997)
Characterization of a hard x ray telescope at a synchrotron...
Proceedings of SPIE (September 08 2005)

Back to Top