Paper
10 July 2018 Design and performances of an optical metrology system to test position and tilt accuracy of fiber positioners
Luzius Kronig, Philipp Hörler, Jean-Paul Kneib, Mohamed Bouri
Author Affiliations +
Abstract
This paper describes the design of an optical metrology system for fiber positioners. The system can be used for accurate calibration and verification of fiber positioners with SCARA-like RR planar kinematics. It is capable of measuring accurately the absolute position and tilt of the fiber tip over the whole workspace of the positioner. The metrology system works by back illuminating the optical fiber of the positioner with a laser. The position and tilt of the exiting cone at the tip of the fiber is measured with two optical cameras.
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Luzius Kronig, Philipp Hörler, Jean-Paul Kneib, and Mohamed Bouri "Design and performances of an optical metrology system to test position and tilt accuracy of fiber positioners", Proc. SPIE 10706, Advances in Optical and Mechanical Technologies for Telescopes and Instrumentation III, 107066B (10 July 2018); https://doi.org/10.1117/12.2313982
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Cameras

Calibration

Metrology

Optical metrology

Kinematics

Optical fibers

Distortion

RELATED CONTENT

MANIFEST metrology toolkit
Proceedings of SPIE (January 03 2020)
Microlens array analysis using image processing techniques
Proceedings of SPIE (January 01 1992)
Geometric errors in 3D optical metrology systems
Proceedings of SPIE (August 29 2008)

Back to Top