Paper
29 July 1993 Application of image restoration and three-dimensional visualization techniques to frog microvessels in-situ loaded with fluorescent indicators
Stamatis N. Pagakis, Fitz-Roy E. Curry, Joyce F. Lenz
Author Affiliations +
Proceedings Volume 1905, Biomedical Image Processing and Biomedical Visualization; (1993) https://doi.org/10.1117/12.148706
Event: IS&T/SPIE's Symposium on Electronic Imaging: Science and Technology, 1993, San Jose, CA, United States
Abstract
In situ experiments on microvessels require image sensors of wide dynamic range due to large variations of the intensity in the scene, and 3D visualization due to the thickness of the preparation. The images require restoration because of the inherent tissue movement, out-of- focus-light contamination, and blur. To resolve the above problems, we developed an imaging system for quantitative imaging based on a 12 bits/pixel cooled CCD camera and a PC based digital imaging system. We applied the optical sectioning technique with image restoration using a modified nearest neighbor algorithm and iterative constrained deconvolution on each of the 2D optical sections. For the 3D visualization of the data, a volume rendering software was used. The data provided 3D images of the distribution of fluorescent indicators in intact microvessels. Optical cross sections were also compared with cross sections of the same microvessels examined in the electron microscope after their luminal surfaces were labeled with a tracer which was both electron dense and fluorescent. This procedure enabled precise identification of the endothelial cells in the microvessel wall as the principal site of accumulation of the fluorescent calcium indicator, fura-2, during microperfusion experiments.
© (1993) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Stamatis N. Pagakis, Fitz-Roy E. Curry, and Joyce F. Lenz "Application of image restoration and three-dimensional visualization techniques to frog microvessels in-situ loaded with fluorescent indicators", Proc. SPIE 1905, Biomedical Image Processing and Biomedical Visualization, (29 July 1993); https://doi.org/10.1117/12.148706
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Point spread functions

3D image processing

Luminescence

Image restoration

Visualization

Tissues

Tissue optics

Back to Top