In tins paper ,the cutter magnetizing treatment device is introduced. lools are treated by a I)tlISe niagnetic field of high intensity in it SO S to eliniinate or reduce internal stress of tool face a 0(1 1)lade ,arl 1 e ii g t h e n tool life. I'be resu 1 ts of test and a 1)Plicatiofl have shown that the (ItViC( is very sinpIe in nianufacttiring ail easy in tising ; treating time is less than a minute; Cli t ter strea tC(l have no Tilagnetislil atlil can be used ininiediately ; tool average life 'an be increased by a factor of (20-50) % ,tlie highest increase is about twice.
Deqiang Mu,Qing Fa Ji,Yu Yang, andRuo Ju Li
"Cutter magnetizing treatment devices", Proc. SPIE 2101, Measurement Technology and Intelligent Instruments, (22 September 1993); https://doi.org/10.1117/12.156456