Paper
1 April 1996 Ocular hazards of tunable continuous-wave near-infrared laser sources
David J. Lund, Peter R. Edsall, Douglas F. Fuller, Stephen W. Hoxie
Author Affiliations +
Abstract
Retinal damage thresholds (ED50s) were determined in Rhesus monkey eyes for 100 ms exposures to collimated radiation from a tunable Ti:Sapphire laser at several wavelengths from 700 nm to 900 nm. Prior research using 15 ns duration laser pulses showed a strong variability of ED50 with wavelength for retinal exposure in Rhesus monkeys to laser radiation in the near infrared spectrum. Current studies with the Ti:Sapphire laser show similar variability of ED50 with wavelength for 100 ms retinal exposures. Previously measured light transmission and absorption properties of ocular tissues do not provide a complete or obvious explanation for the significant variations of threshold with small changes in wavelength. Similar wavelength dependencies of ED50 for the two exposure durations in the wavelength range of 750 nm to 830 nm suggest that linear absorption is a cause of the variability. However, differences in the ED50 curves at other wavelengths show that nonlinear mechanisms also contribute.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
David J. Lund, Peter R. Edsall, Douglas F. Fuller, and Stephen W. Hoxie "Ocular hazards of tunable continuous-wave near-infrared laser sources", Proc. SPIE 2674, Laser-Inflicted Eye Injuries: Epidemiology, Prevention, and Treatment, (1 April 1996); https://doi.org/10.1117/12.237518
Lens.org Logo
CITATIONS
Cited by 7 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Absorption

Sapphire lasers

Eye

Near infrared

Retina

Tissues

Chromophores

RELATED CONTENT


Back to Top