17 February 1997 Analysis of the volatile organic compounds in seized cocaine hydrochloride
Lindy Espina Dejarme, Sara J. Lawhon, Prasenjit Ray, Michael R. Kuhlman
Author Affiliations +
Proceedings Volume 2937, Chemistry- and Biology-Based Technologies for Contraband Detection; (1997) https://doi.org/10.1117/12.266769
Event: Enabling Technologies for Law Enforcement and Security, 1996, Boston, MA, United States
Abstract
The volatile organic compounds in seized cocaine hydrochloride were analyzed using Gas Chromatography Mass Spectrometry (GC/MS). Two different methods of sampling volatile compounds were investigated. In the first method, 20, 50, and 100 mg samples of seized cocaine hydrochloride were loaded into 2-inch glass tubes. The headspace of each tube was then purged with ultra high purity (UHP) helium and the gas exiting the tube was directed through a cryogenic loop filled with glass beads and maintained at liquid nitrogen temperature. The volatile organic compounds were collected onto the glass beads while the helium gas was vented. The organic compounds were subsequently thermally desorbed onto the column and analyzed by GC/MS. In the second method, 10 mg and 100 mg samples of seized cocaine hydrochloride were loaded into glass tubes fitted with glass frits at one end. UHP helium was purged through each sample and the purge gas containing organic compounds was collected onto a sorbent tube packed with Tenax TA. The concentrated organic compounds were then thermally desorbed onto a 4 m section of a split GC capillary column maintained at -70 degrees C with flow rates of 20-28 ml/min. Flow was returned to 2.8 ml/min during analysis. By sampling the seized samples of cocaine hydrochloride using a cryogenic loop, methanol, methyl ethyl ketone, acetic acid, 2,2,4-trimethyl pentane, 2-methyl pentane, dichloromethane, 2-propanol, and 2-propanol, and 2-propane (acetone) were found in three different seized cocaine hydrochloride samples. The observed quantities of these volatile organic compounds were different for each of the three seized cocaine hydrochloride samples. THe observed quantities of these volatile organic compounds were different for each of the three seized samples labeled A, B, and C. By sampling the seized samples of cocaine hydrochloride using sorbent tubes, cocaine was consistently observed. Although volatile components other than cocaine were observed, the number and amount of volatile components were not consistent with the cryogenic loop results.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Lindy Espina Dejarme, Sara J. Lawhon, Prasenjit Ray, and Michael R. Kuhlman "Analysis of the volatile organic compounds in seized cocaine hydrochloride", Proc. SPIE 2937, Chemistry- and Biology-Based Technologies for Contraband Detection, (17 February 1997); https://doi.org/10.1117/12.266769
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Glasses

Cryogenics

Magnesium

Helium

Statistical analysis

Liquids

Capillaries

RELATED CONTENT

Capillary electrophoresis for drug analysis
Proceedings of SPIE (February 04 1999)
Kinetic parameters and thermal stability of metalloporphyrins
Proceedings of SPIE (November 01 2012)
First concept for the E-ELT cryogenic infrastructure
Proceedings of SPIE (July 22 2010)
SIRTF telescope test facility: the first year
Proceedings of SPIE (October 14 1996)
Performance of the SCUBA-2 dilution refrigerator
Proceedings of SPIE (July 18 2008)

Back to Top