Abstract
The Spallation Neutron Source (SNS) under construction at the oak Ridge National Laboratory will be the most important new neutron scattering facility in the United States. Neutron scattering instruments for the SNS will require large area detectors with fast response (< 1 microsecond), high efficiency over a wide range of neutron energies (0.1 to 10 eV), and low gamma ray sensitivity. We are currently developing area neutron detectors based on a combination of 6LiF/ZnS scintillator screens coupled to a wavelength- shifting fiber optic readout array. A 25 X 25-cm prototype detector is currently under development. Initial tests at the High Flux Isotope Reactor have demonstrated good imaging properties coupled with very low gamma ray sensitivity. In addition, we have developed a multi-layer scintillator/fiber detector to replace existing He-3 gas detector tubes for higher speed operation. This detector has demonstrated a neutron detection efficiency of over 75% at a neutron energy of 0.056 eV or about twice thermal. The response time of this detector is approximately 1 microsecond. Details of the design and test results of both detectors will be presented.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Donald P. Hutchinson, Roger K. Richards, David Eugene Holcomb, and James A. Ramsey "Position-sensitive scintillation neutron detectors using a crossed-fiber optic readout array", Proc. SPIE 3769, Penetrating Radiation Systems and Applications, (1 October 1999); https://doi.org/10.1117/12.363669
Lens.org Logo
CITATIONS
Cited by 7 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Scintillators

Particles

Photomultipliers

Optical arrays

Zinc

Electronics

RELATED CONTENT

Cobalt 60 as a marking agent
Proceedings of SPIE (July 19 1996)
Edge reclamation in position-sensitive photomultiplier tubes
Proceedings of SPIE (October 19 1999)
Radiation pager
Proceedings of SPIE (January 06 1997)
Neutron detectors based on CMOS solid state photomultipliers
Proceedings of SPIE (September 03 2008)
An imaging neutron/gamma-ray spectrometer
Proceedings of SPIE (October 19 2012)

Back to Top