Refractive microcapillary lens for hard X-rays is presented. The lens is designed as glass capillary filled by a large number of biconcave microlenses. Fabrication technique for the lens is described. It is shown that the microlenses have a spherical shape. The spherical aberrations of the lens are calculated. The possibility of production of micrometer sized X-ray beams by using the microcapillary X-ray lens is discussed.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.
The alert did not successfully save. Please try again later.
Yury Ivanivich Dudchik, Nikolai N. Kolchevsky, "Fabrication technique and ray tracing calculations for microcapillary x-ray lens," Proc. SPIE 4145, Advances in X-Ray Optics, (5 January 2001); https://doi.org/10.1117/12.411643