Abstract
The E2V CCD42-20 NIMO type CCD was tested in view of its use for the german astrometric satellite mission DIVA. As in other astrometric missions (FAME, GAIA) the CCDs will be operated in TDI mode synchronous with the stars drifting across the detectors. At the expected operating temperature, around -30C to -50C, the dark current performance is an important parameter. Radiation induced degradations with respect to dark current and CTE are of particular concern, too. We find that TDI operation reduces the dark current by a factor of ≈30 near the DIVA satellite TDI clock rate (1.4 msec). The detector was irradiated with soft protons, in a first run, with rather weak doses of up to an equivalent 10 MeV fluence of 1.6×108 protons/cm2. The increase in dark current is quite small (4% to 5% maximum at -40C) but seems to vary with temperature (e.g. 2% at -60C). The CTE degradation shows a linear dependance on the radiation dose and the CTE gets worse if the detector temperature gets lower (e.g. for the highest dose: 0.999 98 at -60C and 0.999 95 at -100C). Vertical and horizontal deferred charge patterns show a significant difference. The total mission dose will be about 10x higher and the dark current and CTE values are tentatively extrapolated. The results of this study shall serve as a basis for further irradiation experiments combined with laboratory simulations and numerical modelling. During the course of this study the DIVA project had to be stopped due to lack of funding. But our results are applicable equally well to the proposed SMEX mission AMEX which is based on the DIVA concept.
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Klaus Reif, Henning Poschmann, Karl-Heinz Marien, and Philipp Mueller "Performance tests of a DIVA-CCD: before and after proton irradiation", Proc. SPIE 5167, Focal Plane Arrays for Space Telescopes, (12 January 2004); https://doi.org/10.1117/12.507128
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Charge-coupled devices

Sensors

Satellites

Iron

Aluminum

Particles

Temperature metrology

RELATED CONTENT

Analysis of influence of anomaly zone in south Atlantic on...
Proceedings of SPIE (November 05 2020)
Recent developments with orthogonal-transfer CCD
Proceedings of SPIE (April 25 1997)
A Star Mapper Using Linear CCD Array
Proceedings of SPIE (November 08 1984)

Back to Top