Paper
7 March 2006 OCT corneal elastography by pressure-induced optical feature flow
Author Affiliations +
Proceedings Volume 6138, Ophthalmic Technologies XVI; 61380P (2006) https://doi.org/10.1117/12.648685
Event: SPIE BiOS, 2006, San Jose, California, United States
Abstract
The viscoelastic properties of the cornea are important determinants of the corneal response to surgery and disease. The purpose of this work is to develop an OCT-based technique for non-contact, high-resolution pan-corneal strain mapping using clinically-achievable pressure changes as a stressor. Porcine corneas were excised and mounted on an artificial anterior chamber that facilitated maintenance of a simulated intraocular pressure (IOP). Pressure was controlled and monitored continuously by saline infusion with an in-line transducer and digital monitor. Mounted specimens were positioned under a laboratory-based high-speed OCT system and imaged in three dimensions at various IOP levels. Matlab and C++ routines were written to perform 2-D bitmap cross-correlation analyses on corresponding images at different pressure levels. Resulting correlations produced a likelihood estimate of the 2-D vector displacement of corneal optical features. Strain maps from cross-correlation analyses revealed local areas of highly consistent displacements interspersed with inter-regional variability. Displacements occurred predominantly along axial vectors. Our analysis produces results consistent with expected and observed displacement of the cornea with varying IOP. Cross-correlation analysis of optical feature flow in the corneal stroma can provide high-resolution strain maps capable of distinguishing spatial heterogeneity in the corneal response to pressure change. A non-destructive, non-contact technique for corneal strain mapping offers numerous potential advantages over tensile testing of excised tissue strips for inferring viscoelastic behavior, and the membrane inflation model employed here could potentially be extended to clinical biomechanical characterizations.
© (2006) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Matthew Ford, William J. Dupps Jr., Nikhil Huprikar, Roger Lin, and Andrew M. Rollins "OCT corneal elastography by pressure-induced optical feature flow", Proc. SPIE 6138, Ophthalmic Technologies XVI, 61380P (7 March 2006); https://doi.org/10.1117/12.648685
Lens.org Logo
CITATIONS
Cited by 13 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Cornea

Optical coherence tomography

Tissue optics

Imaging systems

Tissues

Elastography

Image resolution

Back to Top