Paper
15 June 2006 Hard x-ray concentrator experiment for Spectrum-X-Gamma mission
V. Arefiev, M. Pavlinsky, M. Revnivtsev, E. Churazov, M. Gilfanov, M. Kumakhov, I. Lapshov, V. Levin, V. Akimov, N. Semena, A. Tkachenko, A. Vikhlinin, R. Sunyaev
Author Affiliations +
Abstract
Hard X-ray concentrators based on glass poly-capillary lenses (Kumakhov optics) can bring new flavor for the next generation of astrophysical instruments. We discuss the advantage of such a concentrator for missions such as new Spectrum-X-Gamma, for both scanning and pointing observational modes. Even though an X-ray concentrator has no true imaging capabilities and therefore can not compete with grazing incident mirror instruments, it could be quite useful. For pointing observations the instrument with large area poly-capillary glass concentrator combined with small CZT detector sensitive in the 5-80 keV energy range would significantly improve the faint point sources spectroscopy in hard X-rays. This is of particular interest due to recent INTEGRAL and Swift discovery of the large number of obscured AGNs and comparison of their spectra with the spectrum of the cosmic hard X-ray background. The other important areas to be explored are detection of the Ti-44 line in the supernova remnants and detailed study of high-energy hyrolines in the spectra of X-ray pulsars. The expected parameters of the instrument show that it could be an order of magnitude more sensitive compared to standard coded aperture telescopes. We also explore the potentials of the X-ray concentrator in the scanning mode during the survey phase of the mission.
© (2006) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
V. Arefiev, M. Pavlinsky, M. Revnivtsev, E. Churazov, M. Gilfanov, M. Kumakhov, I. Lapshov, V. Levin, V. Akimov, N. Semena, A. Tkachenko, A. Vikhlinin, and R. Sunyaev "Hard x-ray concentrator experiment for Spectrum-X-Gamma mission", Proc. SPIE 6266, Space Telescopes and Instrumentation II: Ultraviolet to Gamma Ray, 62663L (15 June 2006); https://doi.org/10.1117/12.688428
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Solar concentrators

Sensors

Hard x-rays

X-ray optics

Glasses

Lenses

RELATED CONTENT

Two dimensional sub 5 nm hard x ray focusing with...
Proceedings of SPIE (September 27 2013)
Analysis and design of grazing incidence x ray optics for...
Proceedings of SPIE (October 24 2013)
Progress on multi order hard x ray imaging with multilayer...
Proceedings of SPIE (September 18 2015)
X-ray imaging glass micro-pore optics
Proceedings of SPIE (September 20 2007)
Development of full shell foil x-ray mirrors
Proceedings of SPIE (September 13 2012)

Back to Top