Paper
24 March 2008 Verification of optics for the die-to-wafer-like image mask inspection
Author Affiliations +
Abstract
Due to the feature size shrinking, the application of 193nm-ArF scanner systems with high numerical aperture (NA) and the use of resolution enhancement technologies (RET) have been essential for obtaining the desired pattern accuracy on a wafer. Thus the complexity and volume of data required for masks have been rapidly increasing. Moreover, the complexity of mask pattern makes mask inspection increasingly more difficult. The most annoying problem relating to the sensitivity of inspection system is the encountering of false signals arising from nuisance defects. Setting up thresholds in the defect detection algorithm is a difficult task between high sensitivity and less false defect detection. In addition, the effect of variations in defect printability which is strongly dependent on defect types and position must be considered in order to correctly evaluate mask defect inspection procedures. In order to overcome the problems we have previously proposed new algorithm for die-to-wafer-like image (D-to-WI) in real time. This inspection method compares the die, i.e. the wafer image calculated from CAD data, with the wafer-like image calculated from the mask images detected by the mask inspection system. This paper described optimum mask inspection optics for the D-to-WI mask inspection. We verify the optimum mask inspection optics with numerical simulation for various NA and partial coherence of illumination (σ) in the mask inspection optics. The simulated result shows that the optimum mask inspection optics has NA 0.9 and σ=1 for ArF-6%-PSM (Phase Shift Mask) 65/65 nm Line/Space pattern of 193nm-ArF scanner with NA 0.92. In this case the difference of the critical dimensions (CDs) found by D-to-WI and rigorous simulation results from CAD data was less than 1.5nm.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Akira Takada, Toru Tojo, and Masato Shibuya "Verification of optics for the die-to-wafer-like image mask inspection", Proc. SPIE 6922, Metrology, Inspection, and Process Control for Microlithography XXII, 692229 (24 March 2008); https://doi.org/10.1117/12.772359
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Inspection

Photomasks

Semiconducting wafers

Optical inspection

Diffraction

Wafer-level optics

Scanners

Back to Top