19 July 2010 A new image acquisition system for the Kitt Peak National Observatory Mosaic-1 imager
David G Sawyer, Philip N. Daly, Steve B. Howell, Mark R. Hunten, Heidi Schweiker
Author Affiliations +
Abstract
A project is currently underway to upgrade the Kitt Peak National Observatory (KPNO) Mosaic-1 Imager, an 8192 x 8192 pixel CCD array used on the Mayall 4-meter and WIYN 0.9-meter telescopes. Mosaic-1 has been a heavily subscribed instrument by the US astronomical community since it was commissioned more than a decade ago. In recent years, however, the reliability and efficiency of Mosaic-1 has declined due to aging and failing components. In addition, servicing has become more and more difficult as spare parts are used up, replacement parts become unavailable, and technical expertise for the out-dated controller technology diminishes. The Mosaic-1 upgrade project addresses these reliability and servicing concerns by replacing the CCDs with modern detectors and replacing the controllers with a MONSOON image acquisition system. The upgrade will also enhance the scientific productivity of the instrument through reduced read times, lower read noise, and improved quantum efficiency. We will describe the project status, the technical requirements related to the installation of new CCD detectors and MONSOON controllers, the configuration of the system, and integration of the system into the existing instrument and telescope environments.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
David G Sawyer, Philip N. Daly, Steve B. Howell, Mark R. Hunten, and Heidi Schweiker "A new image acquisition system for the Kitt Peak National Observatory Mosaic-1 imager", Proc. SPIE 7735, Ground-based and Airborne Instrumentation for Astronomy III, 77353A (19 July 2010); https://doi.org/10.1117/12.857619
Lens.org Logo
CITATIONS
Cited by 8 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Charge-coupled devices

Sensors

Imaging systems

Telescopes

Quantum efficiency

CCD image sensors

Connectors

RELATED CONTENT

The PAU camera
Proceedings of SPIE (July 19 2010)
MWIR COMIC imaging camera for the ADONIS adaptive optics system
Proceedings of SPIE (September 29 1995)
8-megapixel thermoelectrically cooled CCD imaging system
Proceedings of SPIE (March 14 1995)
MCP image intensifier with improved DQE
Proceedings of SPIE (July 01 1990)
Commissioning of a 4Kx4K CCD mosaic and the new ESO...
Proceedings of SPIE (July 09 1998)
Upgrade on 61 element adaptive optical system for 1.2 m...
Proceedings of SPIE (October 25 2004)

Back to Top