1 January 1987 Changes In Surface Figure Due To Thermal Hysteresis
S. F. Jacobs, S. C. Johnston, J. M. Sasian, M. Watson, J. D. Targove, D. Bass
Author Affiliations +
Abstract
Thermal cycling hysteresis affects surface figure in low-expansivity mirror substrates. Zerodur, ULE, and Cer-Vit 8-in.-diameter mirrors and dilatometer samples were thermally cycled at uniform rates of 6 K/hr and 60 K/hr, and somewhat faster for nonuniform heating. Figure distortions as large as λ/10 were observed following nonuniform heating of standard Zerodur, which was the only material exhibiting thermal hysteresis. A new experimental Zerodur appears to be free of this problem.