6 March 2013 Spectra optimization for dual-energy contrast-enhanced breast CT
Author Affiliations +
Proceedings Volume 8668, Medical Imaging 2013: Physics of Medical Imaging; 86681Z (2013) https://doi.org/10.1117/12.2006911
Event: SPIE Medical Imaging, 2013, Lake Buena Vista (Orlando Area), Florida, United States
Abstract
This work investigates a dual-energy subtraction technique for cone-beam breast CT combined with an iodinated contrast agent. Simulations were performed to obtain optimally enhanced iodine-equivalent and morphological images. The optimal x-ray beam energies and average glandular dose allocation between the LE and HE images were identified. Cylindrical phantoms were simulated with 10, 14 and 18 cm diameters and composed of 50% fibroglandular breast tissue equivalent material. They contained spherical lesion inserts composed of 0, 25, 75 and 100% fibroglandular equivalent tissues, homogeneous mixtures of 50% fibroglandular equivalent tissue and 0.5, 1.0, 2.5 and 5.0 mg/cm3 iodine, as well as pure calcium hydroxyapatite, emulating calcifications. An acquisition technique with 600 projection images is proposed. Only primary x-ray photons were simulated and a perfect energy-integrating detector was considered. LE and HE beams ranging from 20 keV to 80 keV were investigated. The LE and HE projections were reconstructed using a filtered backprojection algorithm. The LE volume provided the morphological image while the iodine-equivalent volume was obtained by recombining the LE and HE volumes. Contrast-to-noise ratio (CNR) between the spherical inserts and background breast tissue normalized to the square root of the total AGD (CNRD) was used as figure-of-merit for lesion detectability. Based on maximizing CNRD, a 30keV/34keV LE/HE pair and a ~50/50% LE/HE AGD allocation were found to provide the best possible performance for iodine and morphological imaging for an average size breast.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Pablo Milioni de Carvalho, Ann-Katherine Carton, Sylvie Saab-Puong, Răzvan Iordache, and Serge Muller "Spectra optimization for dual-energy contrast-enhanced breast CT", Proc. SPIE 8668, Medical Imaging 2013: Physics of Medical Imaging, 86681Z (6 March 2013); https://doi.org/10.1117/12.2006911
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Breast

Iodine

Tissues

Monte Carlo methods

Sensors

X-rays

Denoising

Back to Top