1.Molecular Imaging of Atherosclerosis: MotivationsProgression of asymptomatic atherosclerotic lesions is the predominant cause of myocardial infarction, stroke, and ischemic limbs. As such life-threatening events continue to occur despite advances in medical therapies, identification of high-risk lesions will be critical in preventing the occurrence of devastating cardiovascular events. Current atherosclerosis imaging strategies focus largely on the anatomic and physiologic characteristics of vessel narrowing as a consequence of vessel stenosis. While useful, these approaches provide little insight into the biology of atherosclerosis, a critical aspect of plaque progression and complications.1 Identifying the molecular or cellular determinants of high-risk (or “vulnerable”) plaques therefore appears a logical approach to understanding and treating atherosclerosis.2 Toward this end, in vivo molecular imaging is a promising strategy to identify key biological processes that govern atherosclerosis, including inflammation, apoptosis, oxidative stress, and angiogenesis.3, 4 2.Imaging of Atheroma InflammationAtherosclerosis is an inflammatory disease driven by the unregulation of leukocyte adhesion molecules and subsequent recruitment of macrophages and T cells within the vessel wall.1 Once resident in the intima, macrophages imbibe lipid, promoting lipid-laden foam cell formation, smooth muscle proliferation, and localized and systemic inflammation typified by the production of destabilizing proteases, cytokines, and oxidants. Nascent atheromata consequently undergo expansive (positive) remodeling, and years later undergo constrictive (negative) remodeling that results in stenosis formation. During this transformative period, plaques may demonstrate high-risk features including inflammation, a large necrotic core, and a thin fibrous cap.2 Such plaques, termed high-risk or vulnerable, may become acutely disrupted, leading to thrombus formation and acute myocardial infarction. The inflammatory cascade has yielded a number of high-sensitivity molecular imaging targets.3, 4 Macrophages are the critical effectors cell in atherosclerosis and have been clinically imaged by positron emission tomography (PET), magnetic resonance imaging (MRI), and nuclear approaches. Imaging of augmented protease activities (cysteine proteases, matrix metalloproteinases) that destabilize the fibrous cap overlying plaques is a promising, translatable, near-IR fluorescence (NIRF) imaging method to detect plaque inflammation. Leukocyte adhesion molecules [e.g., vascular cell adhesion molecule (VCAM)-I] are another attractive imaging target due to their ability to report on early plaque inflammation, and have been imaged by MRI, NIRF, and ultrasound molecular imaging approaches. In addition, strategies to identify plaque apoptosis, accumulation of oxidized lipids, and angiogenesis are exciting options to identify high-risk plaques. For a detailed discussion of molecular imaging agent reporters for atherosclerosis, see several recent reviews.3, 4 3.NIRF as a Molecular Imaging PlatformNIRF imaging has emerged as powerful in vivo approach for molecular imaging of atherosclerosis, due to (1) its high intrinsic (picomolar) sensitivity, (2) a broad array of attachment chemistries for targeted and activatable imaging agents (discussed later in this paper), (3) efficient transmission of light in the near-IR (NIR) window, (4) a wide array of detection systems spanning ultrahigh resolution (confocal microscopy) to mesoscopic resolution (e.g., catheter-based reflectance imaging) to macroscopic resolution (e.g., fluorescence molecular tomography), and (5) substantial clinical translational capabilities from both a hardware standpoint (e.g., NIRF catheters based on clinical catheters for optical coherence tomography) and imaging agent standpoint [i.e., indocyanine green, a NIR fluorochrome that is Food and Drug Administration (FDA) approved for retinal angiography]. 3.1.Photonic Transmission in the NIR WindowCompared to the visible light range, the NIR spectral region, and more specifically the window, offers attractive characteristics for optical imaging due to lower light absorption by hemoglobin in this wavelength band. This enables practical photon detection even after propagation through several centimeters in tissue, for example, through more than in the human breast5, 6, 7 and more than in muscle tissue or in functional brain measurements.8 By comparison, depths of only a few millimeters of tissue can be visualized with similar SNR statistics in the blue, green, or red light regions, although the exact penetration depth remains strongly dependent on the wavelength selection. The NIR region is similarly crucial when considering intravascular applications. While the geometrical dimensions in catheter-based vessel imaging are significantly reduced compared to breast or brain imaging applications, the blood concentration within vessels is significantly higher than in breast, brain, or muscle tissue, leading to a corresponding increase in the absorption coefficient. It is therefore important to utilize NIR wavelengths to achieve high sensitivity through whole blood. In addition, tissue exhibits reduced autofluorescence in the NIR compared to the visible light range.9 This advantage augments the contrast available to imaging and reduces the need for multispectral methods that may otherwise be necessary to decompose the effects of autofluorescence from the signal detected from a reporter fluorochrome. 3.2.Protease-Activatable NIRF Imaging AgentsThe chemical design of a new class of activatable imaging agents based on protease-mediated cleavage of quenched substrates has dramatically improved the sensitivity of in vivo NIRF imaging. Protease-activatable probes are comprised of 15 to 20 NIR fluorochromes that are conjugated to a high molecular weight methyl poly-(ethylene glycol) (MPEG) poly-L-lysine backbone. A radio labeled version of this backbone safely completed clinical trials.10 As the fluorochromes exist in close proximity, self-quenching of the molecule occurs, leading to an optically “silent” imaging agent. As opposed to conventional fluorochromes (or radioisotopes, magnetic reporters, or microbubbles), these quenched fluorescence substrates generate minimal background signal after injection into the body. In a suitable protease-rich environment, cleavage of the quenched substrate occurs, liberating fluorescence. As opposed to imaging agents that report on protease presence with active site-binders, 11, 12 the background signal of the uncleaved NIRF activatable agent is minimal due to its engineered autoquenched design, and high target-to-background ratios are achievable in vivo.13 In particular, in vivo imaging of inflammatory plaques using activatable NIRF probes targeted to cysteine and matrix metalloproteinases (MMPs) have yielded promising results by both intravital fluorescence microscopy (IVFM) and fluorescence molecular tomography (FMT) detection.14, 15, 16 A first-generation activatable NIRF agent targeted to multiple cathepsins13, 14 (cathepsin B, L, S) is now under development for clinical trials for both vascular and cancer applications.3 By interspersing an oligopeptide construct into the MPEG backbone, second-generation NIRF activatable agents can be constructed with specificities for gelatinase activity15 (MMP-2, MMP-9) and cathepsin K.16 In addition, other protease activities have also been imaged using second-generation NIRF activatable reporters such as thrombin,17 cathepsin D,18 urokinase-type plasminogen activator,19 and cathepsin S.20 3.3.Intravascular NIRF Catheter Sensing of Inflammation in Coronary-Sized VesselsA recently tested NIRF catheter offers a new invasive molecular imaging approach to visualize atheroma inflammation in vivo through blood in coronary-sized vessels.21, 22 3.4.NIRF Catheter DesignThe first-generation coronary artery compatible guidewire is based22 on a clinically translatable optical coherence tomography (OCT) platform (Fig. 1 ). The catheter utilizes as an excitation source a laser diode at a (B&W TEK, Newark, New Jersey) and it collects fluorescence signal at . As the excitation and the emission channels are spectrally close to each other, the laser light is first filtered with a narrow-bandpass interference filter centered at and with a full width at half maximum (FWHM) to remove any residual laser emission present in the fluorescence detection channel. Excitation light is then coupled into a system delivery fiber after passing through a beamsplitter and coupled into the dedicated catheter based on an optical coherence tomography wire (LightLab Imaging Inc., Westford, Massachusetts). The catheter is comprised of a radiopaque floppy tip that allows for x-ray detection, and a outer diameter housing containing a multimode fiber for maximal light collection. A prism at the end of the catheter directs the light at with respect to the catheter axis and focuses the light on a focal spot size of around diameter at a working distance of . The fluorescent light emitted by the contrast agent present within the plaque is then collected back into the catheter, guided to the beamsplitter, and coupled into a separate multimode fiber. The fluorescence signal is next filtered with a dielectrically coated dichroic filter with a cut-on wavelength of to remove any further residual excitation laser component. A sensitive photomultiplier tube (H5783-20, Hamamatsu, Shizuoka, Japan) then detects the residual filtered light. 4.Phantom Simulations of Blood and Tissue Attenuation of NIR LightThe effects of blood and tissue on NIRF signal attenuation were tested using a home-built atherosclerotic vessel wall phantom with fresh rabbit blood, simulated tissue, and a NIRF plaque (Fig. 1). The plaque consisted of a cuvette filled with a solution of 1% Intralipid (Liposyn, Hospira Inc., Lake Forest, Illinois) and India ink (Faber-Castell, Cleveland, Ohio) to match the optical parameters of tissue ( and , respectively). The cuvette mimicking the plaque was rendered fluorescent with an NIR fluorochrome (AF750, , Molecular Probes, Eugene, Oregon), while the overlying nonfluorescent solid tissue phantom consisted of a polyester casting resin (Castin’Craft, ETI, Fields Landing, California) mixed with (Sigma-Aldrich Chemical Co. Inc., Milwaukee, Wisconsin) and India ink. The imaging catheter was next immersed in the vessel phantom (a large container filled with rabbit blood) at variable distances from the NIR fluorescent plaque. As expected, NIR fluorescence light attenuated as function of increasing distance. However, notably, the effects of blood compared to saline were modest in the NIR with decay distance of compared with a decay distance of in saline (Fig. 1), affirming the favorable photonic transmission properties of the NIR window. The tissue thickness, reflecting a simulated fibrous cap overlying the fluorescent plaque, also produced only modest effects on the NIRF signal at a thickness. These experiments demonstrated the feasibility of NIR light detection through intravascular volumes of blood relevant for atherosclerotic plaques. 4.1.Real-Time Intravascular Sensing of NIRF Signals Emanating from Inflamed PlaquesThe first in vivo application of the NIRF catheter was demonstrated using atherosclerotic rabbits harboring inflamed atheromata.22 Angiographically visible lesions were produced by balloon injury of the iliac arteries followed by hypercholesterolemia for (Fig. 2 ). Twenty-four hours prior to in vivo experiments, rabbits received an injection of a first-generation cysteine protease-activatable NIRF agent (Prosense750, VisEn Medical). The NIRF catheter was then advanced percutaneously into the iliac arteries under x-ray fluoroscopic guidance. Manual, repeated digitized pullbacks and voltage recordings were obtained through blood, without balloon occlusion or saline flushing (Fig. 2). In vivo TBRs were calculated in both normal and diseased segments. NIRF signal profiles readily distinguished atheroma from normal segments, as well as from atheroma of saline-injected control rabbits. High in vivo plaque TBRs were detected with values of , compared to saline controls of . To confirm that augmented voltage was plaque specific, the catheter was readvanced to lesions visible on the angiogram. The static NIRF signal was recorded adjacent to plaques and to normal-appearing vessel wall areas on angiography. To further assess the effect of blood absorption on the detected NIRF signal, vessel occlusion and saline flushing ( over ) were performed through a balloon wedge catheter. In the protease agent group only, differences in flush profiles were evident between plaque areas and normal segments. In plaque areas, saline flushing augmented the detected NIRF signal with a peak signal increase of up to . In the protease agent group, macroscopic fluorescence reflectance imaging (FRI) revealed NIRF signal in plaques but not in the uninjured, normal-appearing vessel segment. The in vivo and ex vivo peak plaque TBRs correlated well ( , ), demonstrating reasonable in vivo quantification methodology. In vitro histopathology confirmed colocalization of NIRF signal with cathepsin B and macrophages within atheroma (Fig. 3 ), and demonstrated reduced plaque autofluorescence in the NIR range compared to the visible range, as expected.22 This study thus provided the first demonstration of in vivo molecular imaging of plaque inflammation in coronary-sized vessels. Due to the ability to obtain high TBRs in vivo through blood in real time, this approach appears promising for rapid coronary artery screening in vivo. Additional studies will clarify the attenuation effects of blood in larger vessels (e.g., diameter) than tested in this study ( diameter). 4.2.Intravascular NIRF Catheter Design: Future DirectionsWhile original intravascular fluorescence imaging designs21, 22 have demonstrated feasibility based on 1-D signal acquisition, it is crucial to develop catheter systems with the ability to provide 3-D imaging of vessel segments as necessary for comprehensive coronary arterial imaging. Of importance are methodologies that can offer accurate visualization and impart quantification within the challenging imaging conditions of a blood vessel. A preferred mode of operation is the use of an enclosed rotating fiber, similar to those utilized in intravascular optical coherence tomography systems.23 The combination of the rotating fiber with a pullback mechanism further enables the longitudinal visualization of vessels. Typically, the selection of a large fiber diameter offers high collection efficiency in multimode propagation. A crucial design parameter is the point spread function of the illumination and detection profile, in particular, the beam waist size of the focal spot and the Rayleigh length that define the metrics of energy deposition confinement on the vessel as a function of vessel diameter. Extended Rayleigh lengths (i.e., the length along which the beam stays focused) is particularly important for maintaining relative uniformity of illumination (energy deposition) and resolution during the imaging operation. The design of rotating NIRF imaging catheters enables the possibility of seamless operation with other vessel imaging modalities, for example, with intravascular OCT, intravascular optical frequency domain imaging,24 intravascular NIR spectroscopy,25 or intravascular ultrasound. While chromatic aberrations of the focusing optics must be considered when markedly different spectral zones are utilized for OCT versus fluorescence imaging, the relatively relaxed optical conditions for the noncoherent fluorescence detection will allow for design practices common in currently available intravascular OCT systems. Another advance in intravascular NIRF imaging possible is to employ molecular optoacoustic imaging for visualizing common fluorochromes and other chromophoric reporter molecules,26, 27 or tissue composition features such as fibrous and lipid components. The use of optoacoustics has the capacity to further resolve depth, reaching resolution and penetration capacity that are common to ultrasound systems, but imparting new contrast mechanisms for atherosclerosis differentiation. 5.ConclusionsThe development of a coronary artery-compatible NIRF sensing catheter coupled with a high-sensitivity protease-activatable agent has enabled the real-time sensing of plaque inflammation through blood. Anticipated development of second-generation (imaging, multispectral, optoacoustic) and third-generation (multimodality) NIRF catheters are poised to enable integrated molecular and architectural assessment of coronary plaques in the cardiac catheterization laboratory. The availability of clinical coronary NIRF catheters with FDA-approved NIRF imaging agents will enable (1) new insights into atherosclerosis biology in living patients (in particular, the temporal and spatial characteristics of inflammation in coronary arteries), (2) understanding an individual plaque’s risk of inducing myocardial infarction based on its underlying biological profile, and (3) assessment of novel biologics designed to attenuate inflammation in coronary atherosclerotic plaques. AcknowledgmentsSupport for this work was provided by the Howard Hughes Medical Institute Career Development Award (FAJ), the American Heart Association Scientist Development Grant (FAJ), the Donald W. Reynolds Foundation (FAJ), and the MGH William Schreyer Fellowship (MAC). ReferencesG. K. Hansson,
“Inflammation, atherosclerosis, and coronary artery disease,”
N. Engl. J. Med., 352 1685
–1695
(2005). https://doi.org/10.1056/NEJMra043430 0028-4793 Google Scholar
M. Naghavi,
P. Libby,
E. Falk,
S. W. Casscells,
S. Litovsky,
J. Rumberger,
J. J. Badimon,
C. Stefanadis,
P. Moreno,
G. Pasterkamp,
Z. Fayad,
P. H. Stone,
S. Waxman,
P. Raggi,
M. Madjid,
A. Zarrabi,
A. Burke,
C. Yuan,
P. J. Fitzgerald,
D. S. Siscovick,
C. L. de Korte,
M. Aikawa,
K. E. Juhani Airaksinen,
G. Assmann,
C. R. Becker,
J. H. Chesebro,
A. Farb,
Z. S. Galis,
C. Jackson,
I. K. Jang,
W. Koenig,
R. A. Lodder,
K. March,
J. Demirovic,
M. Navab,
S. G. Priori,
M. D. Rekhter,
R. Bahr,
S. M. Grundy,
R. Mehran,
A. Colombo,
E. Boerwinkle,
C. Ballantyne,
W. Insull Jr., R. S. Schwartz,
R. Vogel,
P. W. Serruys,
G. K. Hansson,
D. P. Faxon,
S. Kaul,
H. Drexler,
P. Greenland,
J. E. Muller,
R. Virmani,
P. M. Ridker,
D. P. Zipes,
P. K. Shah, and
J. T. Willerson,
“From vulnerable plaque to vulnerable patient: a call for new definitions and risk assessment strategies: part I,”
Circulation, 108 1664
–1672
(2003). https://doi.org/10.1161/01.CIR.0000087480.94275.97 0009-7322 Google Scholar
F. A. Jaffer,
P. Libby, and
R. Weissleder,
“Molecular imaging of cardiovascular disease,”
Circulation, 116 1052
–1061
(2007). https://doi.org/10.1161/CIRCULATIONAHA.106.647164 0009-7322 Google Scholar
J. Sanz and
Z. A. Fayad,
“Imaging of atherosclerotic cardiovascular disease,”
Nature (London), 451 953
–957
(2008). https://doi.org/10.1038/nature06803 0028-0836 Google Scholar
B. W. Pogue,
S. P. Poplack,
T. O. McBride,
W. A. Wells,
K. S. Osterman,
U. L. Osterberg, and
K. D. Paulsen,
“Quantitative hemoglobin tomography with diffuse near-infrared spectroscopy: pilot results in the breast,”
Radiology, 218 261
–266
(2001). 0033-8419 Google Scholar
V. Ntziachristos,
A. G. Yodh,
M. Schnall, and
B. Chance,
“Concurrent MRI and diffuse optical tomography of breast after indocyanine green enhancement,”
Proc. Natl. Acad. Sci. U.S.A., 97 2767
–2772
(2000). https://doi.org/10.1073/pnas.040570597 0027-8424 Google Scholar
Q. Fang,
S. A. Carp,
J. Selb,
G. Boverman,
Q. Zhang,
D. B. Kopans,
R. H. Moore,
E. L. Miller,
D. H. Brooks, and
D. A. Boas,
“Combined optical imaging and mammography of the healthy breast: optical contrast derived from breast structure and compression,”
IEEE Trans. Med. Imaging, 28 30
–42
(2009). https://doi.org/10.1109/TMI.2008.925082 0278-0062 Google Scholar
R. D. Hoge,
M. A. Franceschini,
R. J. Covolan,
T. Huppert,
J. B. Mandeville, and
D. A. Boas,
“Simultaneous recording of task-induced changes in blood oxygenation, volume, and flow using diffuse optical imaging and arterial spin-labeling MRI,”
Neuroimage, 25 701
–707
(2005). https://doi.org/10.1016/j.neuroimage.2004.12.032 1053-8119 Google Scholar
M. G. Muller,
I. Georgakoudi,
Q. Zhang,
J. Wu, and
M. S. Feld,
“Intrinsic fluorescence spectroscopy in turbid media: disentangling effects of scattering and absorption,”
Appl. Opt., 40 4633
–4646
(2001). https://doi.org/10.1364/AO.40.004633 0003-6935 Google Scholar
R. J. Callahan,
A. Bogdanov Jr., A. J. Fischman,
T. J. Brady, and
R. Weissleder,
“Preclinical evaluation and phase I clinical trial of a 99mTc-labeled synthetic polymer used in blood pool imaging,”
AJR, Am. J. Roentgenol., 171 137
–143
(1998). 0361-803X Google Scholar
M. Schafers,
B. Riemann,
K. Kopka,
H. J. Breyholz,
S. Wagner,
K. P. Schafers,
M. P. Law,
O. Schober, and
B. Levkau,
“Scintigraphic imaging of matrix metalloproteinase activity in the arterial wall in vivo,”
Circulation, 109 2554
–2559
(2004). https://doi.org/10.1161/01.CIR.0000129088.49276.83 0009-7322 Google Scholar
E. Lancelot,
V. Amirbekian,
I. Brigger,
J. S. Raynaud,
S. Ballet,
C. David,
O. Rousseaux,
S. Le Greneur,
M. Port,
H. R. Lijnen,
P. Bruneval,
J. B. Michel,
T. Ouimet,
B. Roques,
S. Amirbekian,
F. Hyafil,
E. Vucic,
J. G. Aguinaldo,
C. Corot, and
Z. A. Fayad,
“Evaluation of matrix metalloproteinases in atherosclerosis using a novel noninvasive imaging approach,”
Arterioscler., Thromb., Vasc. Biol., 28 425
–432
(2008). https://doi.org/10.1161/ATVBAHA.107.149666 1079-5642 Google Scholar
R. Weissleder,
C. H. Tung,
U. Mahmood, and
A. Bogdanov Jr.,
“In vivo imaging of tumors with protease-activated near-infrared fluorescent probes,”
Nat. Biotechnol., 17 375
–378
(1999). https://doi.org/10.1038/7933 1087-0156 Google Scholar
J. Chen,
C. H. Tung,
U. Mahmood,
V. Ntziachristos,
R. Gyurko,
M. C. Fishman,
P. L. Huang, and
R. Weissleder,
“In vivo imaging of proteolytic activity in atherosclerosis,”
Circulation, 105 2766
–2771
(2002). https://doi.org/10.1161/01.CIR.0000017860.20619.23 0009-7322 Google Scholar
J. O. Deguchi,
M. Aikawa,
C. H. Tung,
E. Aikawa,
D. E. Kim,
V. Ntziachristos,
R. Weissleder, and
P. Libby,
“Inflammation in atherosclerosis: visualizing matrix metalloproteinase action in macrophages in vivo,”
Circulation, 114 55
–62
(2006). https://doi.org/10.1161/CIRCULATIONAHA.106.619056 0009-7322 Google Scholar
F. A. Jaffer,
D. E. Kim,
L. Quinti,
C. H. Tung,
E. Aikawa,
A. N. Pande,
R. H. Kohler,
G. P. Shi,
P. Libby, and
R. Weissleder,
“Optical visualization of cathepsin K activity in atherosclerosis with a novel, protease-activatable fluorescence sensor,”
Circulation, 115 2292
–2298
(2007). https://doi.org/10.1161/CIRCULATIONAHA.106.660340 0009-7322 Google Scholar
F. A. Jaffer,
C. H. Tung,
R. E. Gerszten, and
R. Weissleder,
“In vivo imaging of thrombin activity in experimental thrombi with thrombin-sensitive near-infrared molecular probe,”
Arterioscler., Thromb., Vasc. Biol., 22 1929
–1935
(2002). https://doi.org/10.1161/01.ATV.0000033089.56970.2D 1079-5642 Google Scholar
C. H. Tung,
U. Mahmood,
S. Bredow, and
R. Weissleder,
“In vivo imaging of proteolytic enzyme activity using a novel molecular reporter,”
Cancer Res., 60 4953
–4958
(2000). 0008-5472 Google Scholar
J. K. Hsiao,
B. Law,
R. Weissleder, and
C. H. Tung,
“In vivo imaging of tumor associated urokinase-type plasminogen activator activity,”
J. Biomed. Opt., 11 34013
(2006). https://doi.org/10.1117/1.2204029 1083-3668 Google Scholar
A. K. Galande,
S. A. Hilderbrand,
R. Weissleder, and
C. H. Tung,
“Enzyme-targeted fluorescent imaging probes on a multiple antigenic peptide core,”
J. Med. Chem., 49 4715
–4720
(2006). https://doi.org/10.1021/jm051001a 0022-2623 Google Scholar
B. Zhu,
F. A. Jaffer,
V. Ntziachristos, and
R. Weissleder,
“Development of a near infrared fluorescence catheter: operating characterisitics and feasibility for atherosclerotic plaque detection,”
J. Phys. D: Appl. Phys., 38 2701
–2707
(2005). https://doi.org/10.1088/0022-3727/38/15/024 0022-3727 Google Scholar
F. A. Jaffer,
C. Vinegoni,
M. C. John,
E. Aikawa,
H. K. Gold,
A. V. Finn,
V. Ntziachristos,
P. Libby, and
R. Weissleder,
“Real-time catheter molecular sensing of inflammation in proteolytically active atherosclerosis,”
Circulation, 118 1802
–1809
(2008). https://doi.org/10.1161/CIRCULATIONAHA.108.785881 0009-7322 Google Scholar
G. J. Tearney,
I. K. Jang, and
B. E. Bouma,
“Optical coherence tomography for imaging the vulnerable plaque,”
J. Biomed. Opt., 11 021002
(2006). https://doi.org/10.1117/1.2192697 1083-3668 Google Scholar
S. H. Yun,
G. J. Tearney,
B. J. Vakoc,
M. Shishkov,
W. Y. Oh,
A. E. Desjardins,
M. J. Suter,
R. C. Chan,
J. A. Evans,
I. K. Jang,
N. S. Nishioka,
J. F. de Boer, and
B. E. Bouma,
“Comprehensive volumetric optical microscopy in vivo,”
Nat. Med., 12 1429
–1433
(2006). https://doi.org/10.1038/nm1450 1078-8956 Google Scholar
C. M. Gardner,
H. Tan,
E. L. Hull,
J. B. Lisauskas,
S. T. Sum,
T. M. Meese,
C. Jiang,
S. P. Madden,
J. D. Caplan,
A. P. Burke,
R. Virmani,
J. Goldstein, and
J. E. Muller,
“Detection of lipid core coronary plaques in autopsy specimens with a novel catheter-based near-infrared spectroscopy system,”
JACC Cardiovasc. Imaging, 1 638
–648
(2008). https://doi.org/10.1016/j.jcmg.2008.06.001 Google Scholar
D. Razansky,
C. Vinegoni, and
V. Ntziachristos,
“Multispectral photoacoustic imaging of fluorochromes in small animals,”
Opt. Lett., 32 2891
–2893
(2007). https://doi.org/10.1364/OL.32.002891 0146-9592 Google Scholar
D. Razansky,
C. Vinegoni, and
V. Ntziachristos,
“Imaging of mesoscopic-scale organisms using selective-plane optoacoustic tomography,”
Phys. Med. Biol., 54 2769
–2777
(2009). https://doi.org/10.1088/0031-9155/54/9/012 0031-9155 Google Scholar
|