1.IntroductionMedical imaging in the regime of visual wavelengths, such as diffuse optical tomography (DOT) or fluorescence lifetime imaging (FLI), has emerged as a non-invasive, safe, and cost-effective method to investigate physiologic and/or biological quantities in tissues.1,2 Frequency- or time-domain measurements are widely used data-acquisition methods to improve the system performance in diffusive imaging. These methods measure the frequency-response of diffusive media in addition to the steady-state response (DC). The additional information measured from frequency- or time-domain measurements generally alleviates disadvantages inherent in DC-based diffusive imaging.1,3 For example, the crosstalk between scattering () and absorption () coefficients of reconstructed functional images of tissues in DOT can be dramatically reduced by employing frequency-domain measurement.4,5 Also, the problem of ill-posedness and non-unique solutions typically happens in reconstruction algorithms of tomographic diffusive imaging, which can be effectively managed using frequency- or time-domain measurements.1,6 In addition to acquiring various types of data, such as a frequency-response of tissue, collecting large datasets also enhances system performance in both optical tomography and topography imaging.2 Researchers have considered collecting large datasets using imaging systems with detector arrays, such as charge-coupled device (CCD) or complementary metal-oxide-semiconductor (CMOS) detectors, in diffusive imaging as opposed to conventional fiber-based systems that collect data at relatively a few measurement points.7 It is demonstrated that DC data measured by a CCD can relieve the ill-posedness and improve the resolution of reconstructed images in DOT.8 As another example, a CCD-based DOT system operating at up to 1 GHz frequency of intensity modulation was built for investigating small tissue volume.9 It is also reported that the reconstructed images from fluorescent optical tomography was improved by large DC datasets.10 Recently, the Hotelling observer performance for frequency-domain phased array systems with a detector array is investigated showing that stable and high detectability is achieved at very low modulation frequencies.11 For frequency-domain systems, the intensity of an incident beam is modulated at, typically, hundreds of MHz. The modulation amplitude and phase of an output modulation beam from a tissue are attenuated and delayed due to scattering and absorption characteristics of the tissue. Since the typical modulation frequency in diffusive imaging is usually higher than the achievable sampling rates of current CCD or CMOS detectors, a gain-modulated image intensifier is used to make the modulation amplitude and phase of the output measurable. There are two methods of the gain-modulation measurement: the heterodyne and homodyne methods.3 The heterodyne method makes the output modulate at a beat frequency, that is the difference between source and gain-modulation frequencies. The beat frequency is selected from the purpose of diffusive imaging considering the maximum frame rate of the CCD or CMOS detectors. The homodyne method is conceptually the same as the heterodyne in that a beat frequency output is detected, but the output beam intensity is varied along the beat frequency trajectory by changing the relative phase between gain and source modulations. For this case, the output images are stable in time, so it is easier to average multiple images to reduce measurement noise. The measurement speed of the homodyne method is, however, limited due to instrumentation required to change the modulation phase, which indicates that homodyne measurements might not be appropriate for very fast dynamic diffusive imaging, where heterodyne measurements operating at up to a few kHz beat frequency have the potential to monitor the dynamic variations of biological quantities.12,13 Time-domain systems are conceptually similar to frequency-domain systems. The impulse response function is attenuated and distorted by scattering and absorption in a tissue, which contains the frequency-response information of attenuated amplitude and delayed phase. The time-domain approach has the benefit that one can estimate the frequency-response of tissue for a wide range of frequencies from a single measurement. Furthermore, for very thick tissues, where it is hard in a frequency-domain measurement to extract meaningful data due to very small number of output photons, an impulse response function can be measured by the time correlated single photon counting (TCSPC) method.5,14 However, the instrumentation for time-domain systems is usually more complicated and costly than that of frequency-domain systems. More discussion for the comparison between frequency- and time-domain measurements can be found in Refs. 1 and 3. For both frequency- and time-domain measurements, the estimated DC, amplitude, and phase are random variables due to measurement noise. The randomness of these quantities detrimentally affects tomographic reconstructions employing these quantities as well as biological parameters estimated from these quantities. Therefore, it is important to investigate the statistical characteristics of the frequency-response quantities with an appropriate noise model. V. Toronov et al.15 theoretically derived variances of modulation amplitude and phase in a frequency-domain DOT by Fourier transforming heterodyne outputs with quantum shot noise. These analytic expressions of amplitude and phase variances have been used to investigate optimized modulation frequencies for small volume tissues and to evaluate a CCD-based phased array system in DOT.11,16 In another study, the influence of system parameters on amplitude and phase signal-to-noise ratios (SNRs) was analyzed.17 The statistical characteristics of the frequency-response quantities also play an important role in FLI, where the fluorescent lifetime of fluorophores, an indicator of biological characteristics of tissues, is estimated. Instead of directly measuring the lifetime, which is typically a few or tens of nanoseconds, the frequency-response of fluorophores is measured using intensify-modulated beams. In FLI, the effect of Poisson noise might be significant because the number of fluorescent output photons is occasionally very small (several hundreds).18,19 E. Gratton et al.20 simulated the disagreement of modulation amplitudes and phases between frequency- and time-domain measurements in accordance with output photon counts in FLI. J. Philip and K. Carlsson19 theoretically studied the effect of photon noise on the fluorescent lifetime SNR estimated from various methods, such as lock-in amplifiers, frequency-domain measurements, and demodulation. A. Esposito et al.21 investigated photon economy and acquisition speed in various FLI detection techniques using Monte-Carlo simulations, where they observed that when the number of detected photons is small, the algorithm for estimating the florescent lifetime converges to incorrect values. Recently, Y. Lin and A. Gmitro22 theoretically found out that fluorescent lifetimes estimated by a lock-in amplifier method are biased in the situation of the low number of detected fluorescent photons because of Poisson photon noise. The discrete-Fourier transform is widely used to estimate the attenuated amplitude and delayed phase of the measured heterodyne or homodyne or impulse time response outputs, since it is simple and fast.7,9,14,19–21 In this paper, we derive expressions for means and variances of modulation amplitude and phase that are estimated by Fourier transforming noisy sinusoidal measurements from heterodyne or homodyne methods. Other methods, such as data fitting or maximum-likelihood estimation can be used to extract the frequency-response information, but they generally require more computation time than Fourier analysis.23 When collecting large datasets in diffusive imaging, the computational advantage of Fourier methods over other fitting methods becomes enormous, because the number of detector pixels is very large. Although the kind of methods to estimate modulation amplitudes and phases from measured noisy data might affect the statistics of these quantities, the result of the developed theory in this paper provides insights about the effect of noise on a frequency-domain measurement. The theoretical derivation of the mean and variance of a modulation amplitude and phase is described in Sec. 2. We first develop the theory by considering that sinusoidal outputs are contaminated by temporally uncorrelated noise. Then the derived noise model of heterodyne outputs is applied to the developed results. We theoretically observed that estimated modulation amplitude and phase are severely biased from the actual values, when the number of output photons is small. Furthermore, the amplitude and phase SNRs show large discrepancies from the previously known SNR model of V. Toronov’s et al.15 Sec. 3 shows computational results based on the developed theory. Monte-Carlo simulations are also presented, which verify the characteristics of biases. Extending the developed theory is briefly discussed in Sec. 4 along with conclusions. 2.Theory DevelopmentBy Fourier transforming noisy heterodyne/homodyne measurements, we can estimate the modulation amplitude and phase. We denote the true amplitude and phase as and , and estimates of them as and , respectively. To describe the estimation process, we first describe the Fourier transform of the noisy data evaluated at the beat frequency via where is the noisy photocurrent rate at a detector pixel, which is linearly related to the sinusoidal photon arriving rate [used in Eq. (3)]. is the total measurement time which is usually a multiple of the sinusoidal output period. Increasing implies that more data are used to estimate and . Actually, the photocurrent is measured at discrete, short-interval time points, and the discrete-Fourier transform is employed instead of the continuous transform shown in Eq. (1). Although not shown here, we verified that the theoretical results derived using the continuous transform are equivalent to that of the discrete transform. Thus, we discuss the theory with the continuous Fourier transform for simplicity. As mentioned in the previous section, V. Toronov et al. mathematically derived standard deviations of and considering a shot noise model for the statistics of in Eq. (1). They found that the standard deviation of and to be where and indicate actual DC and AC means of the measured heterodyne output and is a detector-related parameter which is inversely proportional to . The detail expression for is shown in the reference.15 The superscript is used to differentiate standard deviations derived by Toronov et al. from those derived in this paper. The significance of Eq. (2) is that the variances of modulation amplitude and phase can be given by means. However, only a few series terms are considered for the derivation of Eq. (2) assuming and , which are not generally true, as shown in this paper.Assuming temporally uncorrelated noise for in Eq. (1), the mean and covariance for can be written as where In Eq. (3), is the electron charge and and are coefficients related to the conversion of incident photons to output (i.e., current or voltage) in a detector, where the units of and are the same.24 The terms and in Eq. (4) indicate the mean and variance of the noisy sinusoidal photon rate, respectively, which oscillate at , as shown in Eq. (4). For the heterodyne measurement, is a heterodyne beat frequency and indicates the shift of the sinusoidal output from the origin. It is noted that in Eq. (4) becomes constant in time, like the case of thermal noise, when . The terms , , , and in Eq. (4) will be specified later from the known noise model for heterodyne outputs. For mathematical simplicity, exponential functions are considered in the mean and variance of Eq. (4) instead of the co-sinusoidal functions; the final result is unaffected by this consideration.For the statistics of and , the statistics of considering Eqs. (3) and (4) should be investigated first. The mean of is derived as where and are rect and sinc functions, respectively. For a period function, such as Eq. (4), usually , where and is an integer. Resulting from this, Eq. (5) can be simplified, where means of and are respectively. In order to derive the variances of and , second moments, and should be calculated. The mathematical procedure for with Eqs. (1), (3), and (4) is where the conditions for and used for deriving means of Eq. (6) are applied to the last step of Eq. (7). Similarly, the result of can be derived as From Eqs. (7) and (8), the second moments and correlations of and are and respectively. When trigonometric identities are applied to Eqs. (6), (9), and (10), the variances ( and ) and cross covariance of and can be derived as respectively. It is noted that all derived results are for , because the heterodyne output modulates at indicating statistical characteristics of and at are our only concerns.It is reasonable to consider in Eq. (1) is complex multivariate Gaussian from the central limit theorem, because all points of the noisy signal are weighted and summed to form . Considering Eqs. (6) and (11), the random variable transforming25 from of the multivariate Gaussian to generates probability density functions (PDF) for and as and respectively, where and and indicate a ’th order modified Bessel function of the first kind and an error function, respectively. It is noted that is the actual mean of the amplitude of at . Separable PDFs of and , as shown in Eqs. (12) and (13) indicate that these random variables are independent each other. Equations (12(13)–14) imply that plays a critical role for the PDFs of and , which will be investigated in simulation in the next section. Interestingly, is not affected by and in Eq. (4). Expressions similar to Eqs. (12) and (13) were previously reported by S. Morgan.26 However, he did not specify the detailed form and physical meaning of because he derived them from a simple Gaussian noise model.The mean and variance of can be analytically calculated from Eq. (12), which are and respectively. The amplitude mean and variance of Gaussian speckle are equivalently expressed as Eqs. (15) and (16), although physical meanings of speckle are different from the frequency-domain measurement.25 Equations (11) and (16) show that becomes the previously known Toronov model of Eq. (2), only when , which is not generally acceptable, as indicated from Eq. (15). Equation (15) shows that , the mean of estimated from noisy sinusoidal outputs is biased and the amount of bias depends on and in Eqs. (11) and (14). There are no analytic solutions for the moments of , but they can be numerically calculated from Eq. (13). As shown in the next section, calculated from Eq. (13) is also different from and the bias depends on and .With the similar mathematical procedure for calculating moments of and , the mean and variance for estimated DC can be derived from that is substituted to Eqs. (5), (7), and (8), instead of considering . The condition of generates , , , and , which denotes the PDF of is univariate Gaussian. Notice that the variance of , is the same as in Eq. (16) only if . We will observe in simulation that is generally greater than , unless the number of measured photons is very large, so it can be stated that the amplitude variance is generally smaller than the DC variance in frequency-domain measurements. Since is univariate Gaussian, it is not difficult to show that is unbiased. Equations (12)(13)(14)(15)–(16) are generally applied for estimating the amplitude and phase of any sinusoidal signal having the noise property of Eq. (3). Recently, the covariance of a heterodyne and/or homodyne output was theoretically derived from the random amplification of a temporal point process.27 The model of covariance implies that the variance of heterodyne outputs can be expressed as the form of in Eq. (4) and both and are affected by a Fano factor 24 of image intensifiers, which is experimentally verified. A Fano factor is defined by the variance divided by the mean of amplified (secondary) photons per input (primary) photon in image intensifiers. If the gain of an image intensifier in the heterodyne measurement is assumed to be high, and the spatial variation of the amount of primary photons incident on the image intensifier is not abruptly changed, the covariance model specifies and in Eq. (14) as27 and respectively. Terms and are the DC photon rate and the modulation depth of modulating primary photons incident onto an image intensifier. The modulated gain in the image intensifier is generally non-sinusoidal, which can be expanded to Fourier cosine terms of amplitude .28 The subscript in Eqs. (17) and (18) is an integer and indicates the amplitude for the main frequency of the modulated gain. The term is the gain achieved on the micro channel plate (MCP) of image intensifiers, which separately functions from the DC cathode gain . Therefore, indicates the overall image intensifier’s gain. Substituting and of Eqs. (17) and (18) to Eq. (14) produces for the case of heterodyne measurements, which is The term in Eq. (19) indicates the number of primary photons incident into the image intensifier during , which determines the unit of ; it is unitless.3.Simulation Results and DiscussionFigures 1(a) and 1(b) show some examples of and for arbitrarily chosen values of , , and , respectively, to investigate characteristics of these PDFs. The values of and in Eq. (3) are also arbitrarily chosen as 0.5 and 0.6, respectively, which will be maintained for all simulations in this paper. Having , indicates the conversion loss from photons to photoelectrons without an electronic gain in the CCD or CMOS detectors. As expected from the definition of PDF, all PDFs plotted in Fig. 1 are non-negative functions. Although all PDFs appear Gaussian shaped, they are actually not, as mathematically verified from Eqs. (12) and (13). Figure 1 indicates that the asymmetry in both and increases as decreases, which results in biased means. From characteristics of shown in Fig. 1(a), it is expected that is higher than for the smaller value of . Oppositely, the behavior of in Fig. 1(b) shows that is smaller than because the value of is increased around as decreases. From other simulation results, we confirmed that when is negative, around starts increasing as decreases. Therefore, it can be stated that is always under-estimated regardless of its actual mean. Similarly, we observed that is always over-estimated. It can be also conjectured from Fig. 1 that the amount of bias for both and is dependent on their actual mean values. Furthermore, it can be expected that smaller increases the bias of and as well as the standard deviations of and . Since it is definite that is critical for statistics of and , as observed in Fig. 1, it is worth to briefly discuss the effect of heterodyne measurement parameters on in Eqs. (14) and (19). It is clear from Fig. 1 that higher is generally better to correctly estimate and , which is achieved by the larger amount of primary photon, in Eq. (19). If modulating primary photons are assumed to be directly detected without heterodyne and/or homodyne processes, it is reasonable to consider that the main noise for the primary is Poisson. For Poisson photon noise, and in Eq. (14), so is It is straightforward that in Eq. (20) is always larger than that in Eq. (19). This indicates that even though the image intensifier in heterodyne processes amplifies primaries to increase the number of detected secondary photons, the estimation for and is worse because the Poisson noise is also amplified. For Eq. (19), can be increased as and/or increase. As the gain-modulation deviates from a perfect sinusoidal function, in the denominator is more rapidly increased than in the numerator, hence reducing . The term in Eq. (19) is equivalent to the Noise Factor NF, when primary photons are assumed as Poisson.27 Therefore, NF, commonly used in noise analyses for photon amplifiers, affects profoundly. It is known that NF can be minimized with a very high image intensifier gain, which is 3.5 to 4.2 and 1.6 to 2.2 for second- and third-generation image intensifiers, respectively.29 Since NF is increased as the gain decreases, becomes small at low-gain situations.We assumed an image intensifier’s gain is large enough to validate Eqs. (17) and (18), so is selected for simulations. Figure 2 shows percent differences between actual and estimated means for and , respectively, with parameters of , and for in Eq. (19). A value of 1.3 for is considered from the experimental result27 and indicates the summation of is assumed to be 50% of . Considering the typical quantum efficiency of a photocathode in image intensifiers, in is set to 0.3. The larger value among estimated and actual means is used as a denominator to set the percent difference within . Since is usually much longer than the modulation period of the primary, in -axes of Fig. 2 can be considered as the average primary photons during . For frequency-domain diffusive imaging, is largely varied across a phantom exit surface. Thus, and in Fig. 2 are simulated for three different values. As shown in Fig. 2, both and are severely biased when the number of primary photons from a phantom is small, where and show over- and under-estimations, respectively, as expected from the results in Fig. 1. It is verified from other additional simulations that always approaches zero as the primary photon number decreases. Furthermore, Fig. 2(b) indicates the amount of bias for is strongly dependent on , which is consistent with the behavior of in Fig. 1(b). It should be noticed that the typical range of is from hundreds up to ten thousands, so the number of secondary photons for the primaries in Fig. 2 is actually very large. Figure 2 implies that for the diffusive imaging, where the number of output photons from a phantom is small, tomographic functional images or biological quantities estimated from and may be highly inaccurate. Figure 3 shows percent differences between SNR calculated from the derived theory in this paper and SNR () from the previously known model of Eq. (2) for the same parameters as Fig. 2. For , and are assumed to be correct, and , respectively. Like Fig. 2, the larger one between SNR and is used as a denominator for calculating these percent differences. There is a good agreement between SNR and when the primary photon number from a phantom is relatively large. However, the agreement starts deviating as primary photon number is decreased, where and are larger and smaller than and , respectively. For , especially, the primary photon number starting the discrepancy and the amount of the percent difference are magnificently increased, compared with the bias of in Fig. 2. Figure 3 shows that it is not appropriate to estimate system performance based on the previously known noise model for frequency-domain diffusive imaging systems with the small output photon numbers, such as the system observing dynamic variation of biological quantities or FLI. We examine the estimated means and their characteristics using brute-force and Monte-Carlo simulations. For brute-force simulations, we generate sinusoidal signals of one period with known and , where white Gaussian noise is added. Fourier transforming the noise-contaminated signals determines and that are random. Averaging these random variables by repeating brute-force simulations can estimate and . Figure 4(a) shows one example of the noisy sinusoidal signal that mimics a heterodyne or homodyne output. The standard deviation of the noisy data is 10 and the solid line indicates the mean sinusoidal signal. and estimated from the ensemble of the noisy signals are shown in Fig. 4(b) as increasing the standard deviation from 0 to 30. As theoretically investigated, is unbiased for the entire range of the noise level. However, shows the bias estimation, the amount of which is increased as the noise level increases—over-estimated. In order to investigate biased estimations in the situation similar to diffusive imaging, Monte-Carlo simulations are conducted using tMCimg30 for a homogeneous phantom of and . The tMCimg simulator is widely used in diffusive imaging Monte-Carlo simulations, where the Henyey-Greenstein phase function is assumed for scattering. The anisotropy parameter for the Henyey-Greenstein phase function is set to 0.8 in this simulation. The source of a 2 mm diameter injects photons to the phantom, of which number is varied from to , as shown in Fig. 4. The degree of noise on output photons are decreased as the total photon number increases, because the increased photon number is achieved by summing independently simulated outputs. For example, the output from of total photon number is the summation of eight outputs of source photons. The detector array with pixels on the exit side of the phantom collects simulated output photons. Different from brute-force simulations in Figs. 4(a) and (b), temporal functions of output photons on each detector pixel are Fourier transformed to calculate , , and . Since it is obvious that is unbiased from the developed theory and brute-force simulation, the term is investigated instead of to minimize the numerical error of the Monte-Carlo simulations, such as photon number mismatching. Figures 4(c) and 4(d) show the averaged modulation depth () and from the entire detector pixels at fixed modulation frequencies (). Averaging from the entire pixels avoids a heavy computational load because enormous number of simulations is required to calculate means for one detector pixel. Although actual means and are different for different detector pixels, PDFs of and are the same (with different means), as shown in Eqs. (12) and (13), respectively. Therefore, biased estimations would be clearly observed for and averaged from all detector pixels if the theoretical results derived in Sec. 2 are valid. For the comparison, all curves calculated at a fixed are scaled for both and to make the values of the photon number of are the same. Figures 4(c) and (d) show that and are decreased and increased, respectively, as the number of simulated photons increases, which indicates that and are over- and under-estimated. Furthermore, it is observed that the degree of bias is worse for higher , where the number of output photons contributing to the calculation for and is smaller. It is well known that and are decreased and increased, respectively, as increases, which shows the validity of the Monte-Carlo simulations. Although other systematic factors in heterodyne or homodyne measurements, such as a photon amplifier, signal and noise amplification, and photon losses in these brute-force and Monte-Carlo simulations, Fig. 4 clearly shows that characteristics of estimated quantities from simulations are coincident with what expected from the developed theory. As shown from the theory and simulation, increasing the output photon number from a phantom can definitely remedy the bias estimation and make the simplified noise model of Eq. (2) acceptable. This is definitely achieved by increasing the total measurement time which indicates that quite a number of heterodyne and/or homodyne output periods are acquired to estimate and . However, increasing measurement time is not allowed or difficult in some situations, where, for example, the imaging purpose is to observe the dynamic variation of biological quantities, such as hemodynamic changes.31 Alternatively, increasing the DC primary photon rate decreases the amount of bias estimations with a fixed . Because the photoelectron capacity of CCD or CMOS detector pixels is usually limited, however, the gain of image intensifier should be decreased to avoid the saturation of detector outputs for this increased . The lower gain indicates the noise factor NF of the image intensifier should be increased. Resulting from this, in Eq. (19) might not be increased enough to diminish the bias even for the increased amount of primary photons. Percent differences for and with increased NFs are shown in Figs. 5(a) and 5(b), respectively, where NF ranges 4 to 10 and 4 to 16. It was experimentally shown that these NF ranges are easily achieved in common image intensifiers of decreased gain.29 For comparison, results of in Fig. 2 are repeatedly presented in Fig. 5. We assume NF linearly increases for decreasing the MCP gain that makes the number of secondary photons constant for the increased primary photons in Fig. 5. This implies of Eq. (18) is increased by the increased NF. Other simulation parameters in Fig. 5 are the same as Fig. 2. As shown in Fig. 5, the degree of bias is worse than the results in Fig. 2, which is caused by increased NF. Interestingly, the detrimental effect of increased NF is much more significant for than . It is observed in Fig. 5(b) that the effect of increased NF is almost ignorable for cases of smaller than . Higher NF indicates smaller SNR of secondary photons for given SNR of primary photons, which physically means the secondary photons are more random. Figure 5 indicates that estimating modulation amplitude is much more sensitive to the randomness of output photons than phase. 4.Further Discussion and ConclusionWe observed that modulation amplitude and phase and are biased when they are estimated by Fourier transforming the noisy heterodyne outputs. Furthermore, the previously known SNR model for and is not valid when the number of output photons from a phantom is small. It is known that a very high modulation frequency is required to achieve high SNRs for in diffusive imaging for small volume phantoms9,16 because a high modulation frequency increases in Eq. (4). However, the theoretical result in this paper shows that high (i.e., the large amount of phase delay of the modulated incident beam to a phantom) deteriorates the reliability of the estimated phase . Furthermore, the modulation depth in Eqs. (17) and (19) is dramatically decreased as the modulation frequency increases, which further degrades the estimation for . Although recently developed noise models for heterodyne and homodyne measurements indicate that small reduces in Eq. (4),27 the decreased does not improve the estimation for because in Eq. (14) depends on only and . Therefore, it can be importantly noticed that increasing SNR for does not always reduce the degree of bias estimation. In frequency-domain diffusive imaging with a detector array, increasing detecting points usually accompanies decreasing the detector pixel size, which reduces the measured primary photons per pixel. Furthermore, for detector pixels far away from the incident source, the modulation depth as well as the DC photon rate are decreased because of increased scattering and absorbing in the diffusive medium. Therefore, the bias in and is substantially increased for high-dimensional frequency-domain diffusive imaging. Additionally, the typical loss of photons in heterodyne and/or homodyne frequency-domain measurements makes the photon number necessary for correctly estimating and increased. For example, in some types of systems, where the phosphor of an image intensifier is imaged onto a CCD by an imaging system, the amount of photon loss due to the imaging system is usually significant. This loss of photons is equivalent to decreasing primary photons. Although the theory in this paper is derived from Fourier analysis of a noisy sinusoidal signal, it can be expanded for time-domain measurements. In fact, it is reported elsewhere that estimated by Fourier transforming simulated impulse outputs from TCSPC in FLI are under-estimated as compared to the exact values, where the amount of under-estimation becomes larger for a higher modulation frequency.20 Similarly, the Monte-Carlo simulation results in Fig. 4 are calculated by Fourier transforming impulse response functions of output photons at each detector pixel. As long as and are estimated by Fourier transforming a temporal impulse function that is contaminated by temporally uncorrelated noise, the theoretical analysis and characteristics for the statistics of and is very similar with what is observed in this paper. For example, if the impulse output is measured without amplification, in Eq. (4) can be considered as based on that the variance of shot noise induced by a time-variant signal is described by time-averaging the signal.32. The theoretical procedure in this paper is based on a heterodyne measurement, but the similar results can be derived for a homodyne measurement. The lock-in amplifier method is widely used for estimating fluorescent lifetimes in FLI, where two (or more) co-sinusoidal signals are multiplied to measured modulated fluorescent outputs. The relative phases between modulation outputs and multiplied signals are set to be different like in a homodyne method. Therefore, the concept of lock-in amplifier is very similar with that of heterodyne measurement except the photon amplification process in a homodyne method, which is optional in lock-in amplifiers. We expect that this similarity is the reason that fluorescent lifetimes estimated from a lock-in amplifier show bias, when the detected fluorescent photons are small.19,22 Although the theoretical approach22 to show the biased fluorescent lifetime is different from what is presented in this paper, we consider the origin of the phenomenon is conceptually similar with what we have observed in this paper. The effect of noise on modulation amplitude and phase in frequency-domain diffusive imaging was investigated. It was theoretically derived that the Fourier analysis for a noisy sinusoidal signal induces the estimated amplitude and phase to be biased from actual values when the detected photon number is small. By combining the developed theory with the known noise model of heterodyne and/or homodyne outputs, the degree of bias was measured as a function of the number of diffused photons exiting the phantom. Furthermore, physical insight including the effect of heterodyne and/or homodyne measurement parameters on the bias was elucidated. Especially, we showed that the amplitude and phase biases are deteriorated by the increased noise factor of image intensifiers, which is common for heterodyne and homodyne measurements with low-gain image intensifiers. It is interesting that the noise depending on output signal variation (i.e., AC variance on noisy sinusoidal signals) does not affect the estimation of modulation amplitude and phase. Finally, we pointed out that the previously known noise model for the modulation amplitude and phase is not valid for the situation of small output photons. Therefore, considering the known noise model should be careful because, for many frequency-domain diffusive imaging situations, output photon counts are low. In the near future, experimentally measuring the bias for the estimated amplitude and phase will be investigated. Also, it is worth assessing the performance of frequency-domain diffusive imaging systems in photon-limited situations based on statistical properties of the estimated amplitude and phase developed in this paper. ReferencesA. P. GibsonJ. C. HebdenS. R. Arridge,
“Recent advances in diffuse optical imaging,”
Phys. Med. Biol., 50 R1
–R43
(2005). http://dx.doi.org/10.1088/0031-9155/50/4/R01 PHMBA7 0031-9155 Google Scholar
B. W. Pogueet al.,
“Image analysis methods for diffuse optical tomography,”
J. Biomed. Opt., 11 033001
(2006). http://dx.doi.org/10.1117/1.2209908 JBOPFO 1083-3668 Google Scholar
B. Chanceet al.,
“Phase measurement of light absorption and scatter in human tissue,”
Rev. Sci. Instrum., 69 3457
–3481
(1998). http://dx.doi.org/10.1063/1.1149123 RSINAK 0034-6748 Google Scholar
T. O. McBrideet al.,
“Separation of absorption and scattering heterogeneities in NIR tomographic imaging of tissue,”
Biomedical Topical Meetings, 339
–341 Optical Society of America, Washington, D. C.
(2000). Google Scholar
G. XuD. PiaoC. F. BuntingH. Dehghani,
“Direct-current-based image reconstruction versus direct-current included or excluded frequency-domain reconstruction in diffuse optical tomography,”
Appl. Opt., 49 3059
–3070
(2010). http://dx.doi.org/10.1364/AO.49.003059 APOPAI 0003-6935 Google Scholar
S. R. ArridgeW. R. B. Lionheart,
“Nonuniqueness in diffusion-based optical tomography,”
Opt. Lett., 23 882
–884
(1998). http://dx.doi.org/10.1364/OL.23.000882 OPLEDP 0146-9592 Google Scholar
A. B. ThompsonE. M. Sevick-Murace,
“Near-infrared fluorescence contrast-enhanced imaging with intensified charge-coupled device homodyne detection: measurement precision and accuracy,”
J. Biomed. Opt., 8 111
–120
(2003). http://dx.doi.org/10.1117/1.1528205 JBOPFO 1083-3668 Google Scholar
Z. M. Wanget al.,
“Experimental demonstration of an analytic method for image reconstruction in optical diffusion tomography with large data sets,”
Opt. Lett., 30 3338
–3340
(2005). http://dx.doi.org/10.1364/OL.30.003338 OPLEDP 0146-9592 Google Scholar
U. J. NetzJ. BeuthanA. H. Hielscher,
“Multipixel system for gigahertz frequency-domain optical imaging of finger joints,”
Rev. Sci. Instrum., 79 034301
(2008). http://dx.doi.org/10.1063/1.2840344 RSINAK 0034-6748 Google Scholar
G. Y. Panasyuket al.,
“Fluorescent optical tomography with large data sets,”
Opt. Lett., 33 1744
–1746
(2008). http://dx.doi.org/10.1364/OL.33.001744 OPLEDP 0146-9592 Google Scholar
D. KangM. A. Kupinski,
“Signal detectability in diffusive media using phased arrays in conjunction with detector arrays,”
Opt. Express, 19 12261
–12274
(2011). http://dx.doi.org/10.1364/OE.19.012261 OPEXFF 1094-4087 Google Scholar
H. M. Watzmanet al.,
“Arterial and venous contributions to near-infrared cerebral oximetry,”
Anesthesiology, 93 947
–953
(2000). http://dx.doi.org/10.1097/00000542-200010000-00012 ANESAV 0003-3022 Google Scholar
M. Atlanet al.,
“Cortical blood flow assessment with frequency-domain laser Doppler microscopy,”
J. Biomed. Opt., 12 024019
(2007). http://dx.doi.org/10.1117/1.2715184 JBOPFO 1083-3668 Google Scholar
H. E. GreccoP. Roda-NavarroP. J. Verveer,
“Global analysis of time correlated single photon counting FRET-FLIM data,”
Opt. Express, 17 6493
–6508
(2009). http://dx.doi.org/10.1364/OE.17.006493 OPEXFF 1094-4087 Google Scholar
V. Toronovet al.,
“Optimization of the signal-to-noise ratio of frequency-domain instrumentation for near-infrared spectro-imaging of the human brain,”
Opt. Express, 11 2717
–2729
(2003). http://dx.doi.org/10.1364/OE.11.002717 OPEXFF 1094-4087 Google Scholar
H. K. Kimet al.,
“Optimal source-modulation frequencies for transport-theory-based optical tomography of small-tissue volumes,”
Opt. Express, 16 18082
–18101
(2008). http://dx.doi.org/10.1364/OE.16.018082 OPEXFF 1094-4087 Google Scholar
T. Tuet al.,
“Analysis on performance and optimization of frequency-domain near-infrared instruments,”
J. Biomed. Opt., 7 643
–649
(2002). http://dx.doi.org/10.1117/1.1501562 JBOPFO 1083-3668 Google Scholar
M. KollnerJ. Wolfrum,
“How many photons are necessary for fluorescence-lifetime measurements?,”
Chem. Phys. Lett., 200 199
–204
(1992). http://dx.doi.org/10.1016/0009-2614(92)87068-Z CHPLBC 0009-2614 Google Scholar
J. PhilipK. Carlsson,
“Theoretical investigation of the signal-to-noise ratio in fluorescence lifetime imaging,”
J. Opt. Soc. Am. A, 20 368
–379
(2003). http://dx.doi.org/10.1364/JOSAA.20.000368 JOAOD6 0740-3232 Google Scholar
E. Grattonet al.,
“Fluorescence lifetime imaging for the two-photon microscope: time-domain and frequency-domain methods,”
J. Biomed. Opt., 8 381
–390
(2003). http://dx.doi.org/10.1117/1.1586704 JBOPFO 1083-3668 Google Scholar
A. EspositoH. C. GerritsenF. S. Wouters,
“Optimizing frequency-domain fluorescence lifetime sensing for high-throughput applications: photon economy and acquisition speed,”
J. Opt. Soc. Am. A, 24 3261
–3273
(2007). http://dx.doi.org/10.1364/JOSAA.24.003261 JOAOD6 0740-3232 Google Scholar
Y. LinA. F. Gmitro,
“Statistical analysis and optimization of frequency- domain fluorescence lifetime imaging microscopy using homodyne lock-in detection,”
J. Opt. Soc. Am. A, 27 1145
–1155
(2010). http://dx.doi.org/10.1364/JOSAA.27.001145 JOAOD6 0740-3232 Google Scholar
A. ElderS. SchlachterC. F. Kaminski,
“Theoretical investigation of the photon efficiency in frequency-domain fluorescence lifetime imaging microscopy,”
J. Opt. Soc. Am. A, 25 452
–462
(2008). http://dx.doi.org/10.1364/JOSAA.25.000452 JOAOD6 0740-3232 Google Scholar
H. H. BarrettK. J. Myers, Foundations of Image Science, John Wiley & Sons, Inc., Hoboken, New Jersey
(2004). Google Scholar
J. W. Goodman, Speckle Phenomena in Optics, Theory and Applications, Roberts & Company, Englewood, Colorado
(2006). Google Scholar
S. P. Morgan,
“Detection performance of a diffusive wave phased array,”
Appl. Opt., 43 2071
–2078
(2004). http://dx.doi.org/10.1364/AO.43.002071 APOPAI 0003-6935 Google Scholar
D. KangM. A. Kupinski,
“Noise characteristics of heterodyne/homodyne frequency-domain measurements,”
J. Biomed. Opt., 17
(1), 015002
(2012). http://dx.doi.org/10.1117/1.JBO.17.1.015002 JBOPFO 1083-3668 Google Scholar
B. Q. SpringR. M. Clegg,
“Image analysis for denoising full-field frequency-domain fluorescence lifetime images,”
J. Microscopy, 235 221
–237
(2009). http://dx.doi.org/10.1111/jmi.2009.235.issue-2 JMICAR 0022-2720 Google Scholar
S. E. Moranet al.,
“Intensified CCD (ICCD) dynamic range and noise performance,”
Proc. SPIE, 3173 430
–457
(1997). http://dx.doi.org/10.1117/12.294535 PSISDG 0277-786X Google Scholar
D. A. Boaset al.,
“Three dimensional Monte Carlo code for photon migration through complex heterogeneous media including the adult human head,”
Opt. Express, 10 159
–170
(2002). OPEXFF 1094-4087 Google Scholar
T. Durduranet al.,
“Optical measurement of cerebral hemodynamics and oxygen metabolism in neonates with congenital heart defects,”
J. Biomed. Opt., 15 037004
(2010). http://dx.doi.org/10.1117/1.3425884 JBOPFO 1083-3668 Google Scholar
P. J. Winzer,
“Shot-noise formula for time-varying photon rates: a general derivation,”
J. Opt. Soc. Am. B, 14 2424
–2428
(1997). http://dx.doi.org/10.1364/JOSAB.14.002424 JOBPDE 0740-3224 Google Scholar
|