|
1.IntroductionDental hard tissue disease is frequently characterized by mineral loss. Hence, this is a critical factor in its diagnosis and management in terms of carious and erosive lesions. Clinical diagnosis is based upon anatomical site, recurrence, disease progression, extent, tissue involvement, and chronology.1,2 Both acid erosion and caries are driven by acidic pH, either due to external agents (e.g., citrus juices) or naturally occurring metabolites such as lactic acid. Consequently, the two conditions are not necessarily mutually exclusive.3 However, lesion characteristics are not governed by pH alone, exhibiting dependence on the composition of the demineralizing agent.4 Simplified in vitro models have been developed to study dissolution chemistry, etiological factors, and symptomatic features.4 Furthermore, several analytical techniques have found utility for measuring dental mineralization. Transverse microradiography has been used to assess lesion depth and mineral density,5 along with microhardness6,7 testing and scanning electron microscopy for evaluating structural changes that occur during demineralization.8 X-ray microtomography has provided quantitative high-resolution three-dimensional (3-D) mapping of dental lesions9 and mineral density.10 These laboratory techniques have contributed to both the understanding of dental lesions and the development of oral healthcare treatments. However, they are not readily translated directly into the clinic for in vivo patient examination. Consequently, alternative measurement and imaging technologies have been reported in the dental research literature. These include quantitative light fluorescence and optical coherence tomography (OCT),11 which can be used for both laboratory-based in vitro experiments and in vivo clinical research. OCT is attractive because it noninvasively images backscattered light intensity, which has been shown to be sensitive to changes in dental demineralization.12–16 OCT measurements of lesions formed under different demineralizing conditions have not previously been compared using a consistent environment. Furthermore, OCT studies have previously been limited by protocols that require specimens to be moved between demineralization solutions and the imaging equipment. This is a major limitation for longitudinal studies that aim to understand lesion dynamics over time because measurement uncertainty is associated with specimen realignment at each imaging step.17 Therefore, this paper reports a “hands-free” experimental configuration that mitigates against the need for specimen movement at each time point. The primary aim of developing this system was to enable longitudinal OCT measurements of dental mineralization. This paper investigated whether previously established OCT-based measurements could distinguish between lesions formed using different demineralization models. 2.TheoryThe OCT image forming signal is the result of optical backscatter from within a specimen. Spatial variations in the scattering properties of materials lead to image contrast, enabling regions with different optical properties, such as different tissue types,18 to be visualized. Furthermore, disease processes have been shown to modify the scattering properties of biological tissue.19–22 In the single scattering regime, the OCT signal () can be approximated by an exponential decay of the form given as3–25 where represents the axial starting point of a region described by homogeneous optical properties. The optical properties are expressed in terms of the backscattering coefficient and the signal attenuation constant . The signal attenuation constant describes the rate of OCT intensity decrease due to both absorption and scattering. It is a linear combination of the absorption coefficient and the scattering coefficient such that .The phase function is a probability distribution that statistically relates the intensity of light from an incident direction that couples via single scattering into a given scattered direction. The phase function, , can be summarized by the average cosine of the scattering angle, . This is called the anisotropy factor, , where is equivalent to isotropic scattering, total backscatter, and total forward scatter. Both and are proportional to the phase function23,26 integrated over scattering angles (0 to ) and [-arctan numerical aperture (NA) to ], respectively. Furthermore, the ratio is the probability that light will be scattered into the NA of the OCT objective lens. Therefore, if the shape of the phase function is known, can also be determined.26,27 The dominance of either scattering or absorption is described by the albedo,28 such that indicates pure absorption and indicates purely scattering. In applications such as ophthalmology, the operating waveband of OCT can be chosen to minimize optical absorption,29 leading to the assumptions that and, therefore, while maintaining a useful imaging depth.30 Healthy dental enamel is reported to comprise to 93% mineral by volume.31 Hydrated enamel has been reported to exhibit an increased OCT imaging depth compared to dried enamel,32 most likely by refractive index matching in the interprismatic region. Furthermore, at an optical wavelength of 1300 nm, water absorption is much smaller than scattering from enamel.33,34 Therefore, it is assumed that in dental enamel scattering remains the dominant source of signal attenuation. In real OCT systems, the measured OCT signal, , is the product of with the axial coupling efficiency () centered around the focus at and the axial sensitivity roll-off () The calibration scale factor, , facilitates a comparison between different specimens and systems by accounting for systematic coupling efficiency differences. Calibration of the axial variations in detection sensitivity and optical coupling efficiency is necessary when comparing measurements of the optical properties obtained from different axial positions. Typically, and are obtained from a least squares fit of Eq. (1) to segments of OCT A-scans following calibration of the term . Calibration can be achieved by measuring a specimen with known optical properties.23,24 However, even if the anisotropy factor is unknown, a homogeneous scattering phantom with known attenuation coefficient can still provide a relative intensity calibration. Dividing the OCT A-scan profile of a specimen by an equivalent calibration, A-scan yields the expression for the corrected signal where and . The subscript “cal” denotes the properties of the calibration phantom. Therefore, can be obtained experimentally by fitting Eq. (3) to a corrected OCT A-scan. The specimen attenuation coefficient is found from the sum .These expressions have facilitated the use of OCT for quantitative evaluation of the optical properties of collagen gel tissue scaffolds35 and biological tissues,36 such as atherosclerotic plaques,25,37,38 epithelial precancer,39,40 dental caries,11,14,41,42 and enamel structure.43 These methods have been extended to the spatial mapping of , a technique termed both parametric OCT44 and scattering attenuation microscopy.45 In general, it is preferred to measure the calibration function, rather than rely upon a theoretical description. However, in the presence of dental erosion, the specimen surface moves with respect to the system objective lens. Refractive index differences between the specimen and its surrounding medium necessarily lead to a shift in the focal plane position, . Geometrical optics can be used to estimate the expected focal plane shift due to erosion using the following expression:46 The angle, , denotes the peripheral ray of a focused beam propagating through a medium having refractive index , where the focusing lens is located at along the optical axis, at which the collimated beam radius is . A specimen having refractive index is located such that its surface is perpendicular to the optical axis at . Upon passing into the second medium, the peripheral ray is refracted to a new angle, . The axial location at which the beam would have come to focus in the absence of the specimen is .Assuming an objective NA of , , mm, , (water),47,48 (enamel),49 and , then a shift in the surface position, , corresponds with a focal shift of . The coupling efficiency term, , in Eq. (2) is sensitive to the focal position according to the following equation: where is the beam waist at the focus () with illumination wavelength of .The measured OCT intensity is a product of the coupling efficiency and the scattering slope. It, therefore, follows that variation in the focal plane will lead to variation in measurements of . This uncertainty was explored by a Monte Carlo simulation whereby a uniform distribution of 1000 focal shifts was generated over the range , and corresponding OCT signals were produced using Eq. (2) with and . An exponential function of the form given in Eq. (3) was fitted to each of the simulated OCT curves, resulting in a distribution of estimates for . The standard deviation was equivalent to a 5% variation from the expected value. 3.Materials and Methods3.1.Bovine Enamel SpecimensTwelve bovine incisors were prepared and embedded into 25–mm–diameter clear resin substrates. Each tooth was sectioned into a 6–mm–diameter disk, sliced in the coronal plane to an approximate thickness of 2.6 mm. The enamel surface was exposed by polishing to a flat specular finish, leaving a residual enamel thickness of on top of the underlying dentine. The specimens were prepared by Modus Laboratories Ltd., Reading, UK. 3.2.Artificial Lesion ModelsArtificial lesions were produced by continuous exposure of the enamel to one of three different demineralization solutions. 3.2.1.Citric acid “erosion model” (pH 3.8)A diluted citric acid model, previously used for erosion studies,50–52 was prepared as 0.05 M citric acid (Sigma–Aldrich, UK). The solution was buffered to pH 3.8 using sodium hydroxide (NaOH) pellets. 3.2.2.Acetic acid “caries-like demineralization” model (pH 4.0)A diluted acetic acid model, previously reported for demineralization studies,53 was prepared as 0.17 M acetic acid, buffered to pH 4.0 by the addition of NaOH pellets (Sigma–Aldrich, UK). 3.2.3.Acetic acid “caries-like” model (pH 4.4)Caries models typically contain a source of calcium and phosphate, enabling a subsurface lesion to form while maintaining an intact surface.54–57 Thus, the caries-like model solution was prepared as 2.2 mM , 2.2 mM , and 0.05 M acetic acid with the pH adjusted to 4.4 with 1 M NaOH. 3.3.Optical Coherence Tomography System Specification and ConfigurationThe OCT system used for this study was custom designed and built in-house at Queen Mary University of London. The instrument incorporated a fiber optic Mach–Zehnder58 interferometer design utilizing a super-luminescent light–emitting diode optical source (SLD1325, Thorlabs Ltd., Cambridge, UK), operating with a nominal central wavelength of 1310 nm and bandwidth of . The axial and transverse resolutions were nominally 7 and in air, respectively. Interference fringes were detected by a high-speed spectrometer, comprising an InGaAs linear detector array (SU-LDH2, Sensors Unlimited), a reflective diffraction grating and focusing/collimating achromatic doublet lenses. Images were obtained by raster scanning the probe beam over the tissue surface using a two-dimensional galvanometer configuration (GVS012, Thorlabs, Cambridge, UK). The light was focused beneath the sample surface by a scan lens (Thorlabs LSM03). The system acquired and processed 3-D OCT data in real time using a general-purpose graphics processing unit (NVIDIA C2070).20 A multispecimen holder was fabricated from transparent poly(methyl methacrylate) (PMMA) comprising five isolated flow cell chambers. A typical chamber is shown in Fig. 1, each chamber measured (), having an actual volume of 2.3 mL. The true volume was slightly less than the cuboid volume due to rounded chamber edges. A single piece PMMA lid covered the compartments with each being isolated by a rubber O-ring. The chambers accommodated of solution with the specimen and resin disk occupying the remaining volume (1.5 mL). An inlet channel was placed at the bottom of each chamber with an outlet placed at the top. Solution was flowed through the chambers at a rate of by a motorized pump (, Watson Marlow, UK). Solution was coupled in and out of the chambers by 21 gauge syringes. The OCT probe was mounted onto a linear translation stage (LTS300/M, Thorlabs, UK) such that the probe beam propagated horizontally, parallel to the lab bench. The specimens were mounted vertically in the specimen holder with the exposed enamel face perpendicular to the OCT probe beam. This configuration is shown in Fig. 2. 3.4.CalibrationThe axial collection efficiency of the OCT system and the sensitivity roll-off were calibrated by measuring a weakly scattering phantom.23 This has been previously described as a point spread function phantom,59,60 comprising a low concentration of FeO nanoparticles having an average interparticle spacing of . The well-spaced particles yielded and thus the effect of signal attenuation due to scattering was considered negligible. An area of the phantom surface measuring was measured using the OCT system. The phantom was mounted in the specimen holder and submerged in deionized water to the match the configuration of the demineralization experiments. The mean of 250,000 A-scans was used to represent the average calibration curve by which all subsequent OCT A-scans of the specimens were divided. The calibration curve is shown in Fig. 3. The curve is interrupted by several small sharp peaks that correspond with the spatial frequencies of spurious spectrometer signals and background OCT system reflections. 3.5.Measurement ProtocolThe specimens were initially stored dry in sealed containers at a temperature of 23°C. The samples were immersed in deionized water for 24 h prior to initiation of demineralization and OCT measurement. This mitigated against hydration effects influencing the OCT signal during the initial stages of the experiment. Four hydrated specimens and one reference phantom were placed into each well of the specimen holder. The reference phantom was a polished epoxy block, loaded with scattering particles having a known scattering coefficient23 of , thus providing a constant benchmark for the OCT measured light backscattering intensity. The polished enamel surface was orientated toward the OCT probe beam as shown in Fig. 2. Initially, deionized water was pumped into the flow cell and the central region of the specimen imaged using the OCT system. This was accomplished under computer control such that the alignment of the experimental system was not disturbed. The water was then removed from the specimen wells and replaced with demineralization solution in each chamber using the computer–controlled pump. Filling and emptying of the chambers were completed in a few seconds at a flow rate of . However, during the acid challenge, the solution was flowed continuously at a rate of . The solution was not recycled but drawn from a reservoir of stock demineralization solution. The OCT system automatically acquired a 3-D dataset from a set location within each sample at a minimum of 1-h intervals. Therefore, longitudinally acquired OCT image volumes of each specimen were spatially coregistered. 3.6.Lesion Depth and Optical Properties MeasurementQuantitative analysis of the OCT measurements was automated from the raw data using a script written in the MATLAB® programming language. OCT A-scans were processed from the detected spectral interference patterns into linear intensity profiles. The approximate specimen surface location was known a priori due to the nature of the experimental setup and specimen holder. This information was used to approximately locate the surface reflection peak. The mean of 100 adjacent A-scans was found, from which the intensity maximum was assumed to represent the specimen surface location. The lesion depth, , was estimated by fitting the sum of two Gaussian functions of the form given in the below equation to the OCT signal intensity region around the lesion, In the above equation, the two Gaussian functions are denoted by the subscript and 2. The peak height of the functions is given by , peak location , and half width . Thus, the lesion depth was estimated as Subtracting a systematic offset from the final value to ensure that the lesion thickness was always zero at .This method was chosen empirically because it proved to be stable for automation, comparing well with manual measurements. Specifically, and were incorporated into Eq. (7) because they increased they sensitivity of both to the varying reflection caused by surface erosion and demineralization at the lesion front as it extended into the sound enamel. A typical fit of Eq. (6) to a measured lesion mean A-scan is shown in Fig. 4 as a solid line compared to the measured data points (circles). The two Gaussian functions are shown independently as dotted and dashed lines. Parameters obtained from the lesion depth fit were also used to define a region of interest (ROI) from which the optical properties were estimated. Typically, the peak reflection was high compared to the backscattered intensity from beneath the surface due to the refractive index mismatch between the demineralizing solution and the tooth. Therefore, the peak was filtered out by selecting an ROI from the A-scan, starting 2 pixels () below the surface peak at and extending across the lesion to . The ROI selection is indicated in Fig. 4. Equation (3) was fitted to the extracted subregion, providing output estimates of and . For each series of longitudinal measurements, the percentage change in was calculated at each measurement time as Assuming and , then . Therefore, from here on, the measured attenuation coefficient is referred to as the scattering coefficient. The mean scattering coefficient and the corresponding standard error of the mean were calculated at each time point across all specimens within the model group.4.ResultsCentral B-scans from the citric, acetic, and caries-like models are shown in Figs. 5, 6, and 7 respectively, at baseline (a) and following acid challenge of 6 h (b), 12 h (c), and 24 h (d). Visually, all three models followed similar patterns of progression. At baseline, the dentine–enamel junction was visible, but this became increasingly difficult to discern with increasing duration of acid challenge. At and below the surface, a distinct band of high backscatter (lighter region) was observed to form. Following 6 h of continuous acid challenge, the citric acid model [Fig. 5(b)] showed signs of surface roughening, departing from the smooth profile in Fig. 5(a). Following 24 h of acid challenge, there was visible erosion of the enamel surface relative to the varnished region. The acetic acid model showed less axial erosion. However, the band of intense backscatter extended deeper beneath the surface following 24 h of acid challenge compared with the citric acid model [see Figs. 5(d) and 6(d)]. The caries-like model in Fig. 7 similarly developed a band of intense backscatter, increasing in subsurface depth with acid exposure time. The band itself extended to a similar depth to the citric acid model following 24 h of acid challenge [Fig. 7(d)]. However, there was no perceivable erosion or surface change. The experimental setup ensured spatio-temporal registration of the OCT images. This facilitated direct comparison of quantitative parameters measured from the OCT data. The subsurface lesion depth was measured for each specimen. The mean subsurface lesion depths were compared for each model by plotting their change throughout the acid challenge, Figs. 8(a)–8(c), where the error bars represent the standard error of the mean calculated across the four specimens in each group. The citric acid model [Fig. 8(a)] yielded a maximum subsurface lesion depth of compared with and for the acetic [Fig. 8(b)] and caries-like [Fig. 8(c)] models, respectively. The citric and acetic acid models exhibited a two–stage behavior in the lesion depth formation. This can be seen in Fig. 8(a) (citric) at and Fig. 8(b) (acetic) at . The lesion depth plateaued followed by an instantaneous increase in the growth rate. A similar phenomenon is not clearly evident in Fig. 8(c) for the caries-like model, for which the lesion depth growth rate appeared to be linear for . However, there is arguably a subtle increase in the lesion growth rate around 36 h. The citric and acetic acid solutions are necessarily erosive, albeit with a different pH and ionic composition. Thus, Fig. 8 contains only part of the information with regard to lesion depth. The total lesion depth includes the depth of enamel lost from the surface, shown visually in Fig. 5(d). The sum of surface enamel loss and the subsurface lesion depth is shown in Fig. 9 for all three models at , with error bars representing the standard deviation of the total. The citric acid and caries-like models showed statistically similar subsurface lesion depth measurements (-test, ). However, the citric model was dominated by surface erosion that was absent from the latter due to the addition of calcium chloride and potassium phosphate to the demineralizing solution, which served to maintain the enamel surface. The acetic acid model produced a deeper subsurface lesion, with a relatively small amount of surface erosion. These different lesion characteristics also manifested in terms of the lesion scattering properties, shown in Figs. 10(a)–10(c). The peak scattering coefficient values are in the range to , consistent with values obtained by light transmission measurements.61 However, attenuation values were observed to initially increase to these maxima, followed by a decrease to approximately between 0 and . The acetic acid model [Fig. 10(b)] shows a drop in the attenuation coefficient to , indicating an axially increasing OCT signal intensity. Nevertheless, the postmaximum attenuation curves are visually similar between the models, with a few distinct differences. Each of the models produced attenuation curves with different vertical offsets, i.e., citric acid resulted in a range of attenuation values from to , acetic acid in a range of to , and the caries-like model in a range of to . Similarly, the curves for the different models appear to also be offset in time. Figure 10(a) appears to be shifted left with respect to Figs. 10(b) and 10(c) shifted right by . The different models also appear to be scaled differently along the time axis. The backscattering coefficient, however, exhibited distinctly different behavior between the citric model and both acetic acid–based models. The citric acid model [Fig. 11(a)] yielded a continuous backscattering coefficient decrease of at 48 h. However, both the acetic [Fig. 11(b)] and caries-like [Fig. 11(c)] models show an initial increase ( and , respectively) in the backscattering coefficient followed by a decrease. Notably, after 48 h of acid challenge, the acetic and caries-like models result in a net backscattering coefficient increase of and , respectively. 5.DiscussionThis work has investigated the temporal dynamics of three bovine enamel demineralization models using an automated four-dimensional OCT system integrated with a multispecimen flow cell. This configuration maintained the spatial registration of the OCT image volumes facilitating analysis on the same tissue regions at each acquisition. The specimens were not handled or moved throughout the experiment, thus removing this previously reported source of uncertainty. Figures 8, 10, and 11 all demonstrate that lesion properties vary with time and support the finding that the different models produce detectable differences within the OCT data. The subsurface lesion depth dynamics are distinct between all models. The citric and caries-like lesions showed statistically similar lesion depths at 24 h. However, when plotted with time (Fig. 8), the lesion progression followed a visually different shape. All models produced a subsurface lesion. However, in the citric and acetic models, the depth to which this extended plateaued. This is consistent with the net removal of surface enamel (Fig. 9), which limited the depth of subsurface lesion development. Similar rate limiting behavior has previously been observed in a microradiographic study.62 Furthermore, the same study also reported a secondary increase in the demineralization rate at 24 h for a similar pH 4.0 acetic acid model to that used in this work. This coincides with the discontinuous rate of lesion depth formation observed by OCT in Figs. 8(a) and 8(b), although the exact reason for this behavior is yet to be elucidated. In their work, Anderson et al. attributed it to formation of a surface layer overlying subsurface demineralization. The OCT backscattering coefficient measurements in Fig. 11(b) lend support to this hypothesis with the backscattering maximum observed shortly before the change in lesion depth rate. A similar change is evident in Fig. 11(c), which could support a lesion rate change close to 36 h. There is no corresponding backscattering change in Fig. 11(a), possibly due to the rapid formation of a surface layer.63 Ignoring differences in ionic composition, the lesion depth results indicate that increasing the pH allowed formation of a deeper subsurface lesion while minimizing the loss of surface enamel. It was expected63 that the addition of calcium and phosphate to the demineralization solution resulted in more caries-like lesion formation, maintaining an intact surface. Figure 7 appears to support this, showing little or no change to the surface reflection. However, in this work, the caries-like forming solution has the highest pH at 4.4. The pH scale is logarithmic with respect to hydrogen ion concentration, resulting in a 60% reduction in the caries-like solution compared to the acetic model. Therefore, the results, in this paper, cannot dismiss the possibility that the appearance of an intact surface is a consequence of a slower dissolution of surface enamel. Nevertheless, no surface changes were detected in the OCT data. Measurements of produced discernible differences between each lesion type (Fig. 10). Visually, there was a time offset between the three models, supported by the dissolution rate dependence upon pH.64 However, the theory on which OCT signal slope measurement is based assumes a uniform scattering material. Unfortunately, partial demineralization necessarily leads to local inhomogeneity. Thus, caution must be exercised when quantitatively interpreting these results. The calibration step provides a normalization of the results for reproducibility. However, absolute values of remain to be validated. Nevertheless, the formation of demineralized lesions does alter the local OCT signal intensity and slope (Figs. 5–7). This study attempted to capture this local variation by fitting Eq. (1) to an ROI within the lesion body. The B-scan images [Figs. 5(d), 6(d), and 7(d)] show an increase in backscattered signal intensity at the leading edge of the lesion. Assuming the relationship holds (see Ref. 26), then this might be interpreted as a discontinuous increase in with a consequent local increase in . Somewhat counter-intuitively, this resulted in negative measurements of . This is not physical in the sense that the material provides no gain. However, it does reflect the OCT signal behavior as its intensity increases from the lesion body to its leading edge. One interpretation of this is that initial demineralization removes a small amount of mineral, causing a large refractive index discontinuity between enamel prisms resulting in a large, localized increase in scattering. Continued demineralization decreases the enamel concentration and, therefore, scattering decreases as the lesion body develops. These dynamics were captured in this study by fitting a curve to the lesion and, in this way, demonstrated sensitivity to relative changes with respect to time and demineralization model. However, physical interpretation of the measured values of , including the impact of multiple scattering, remains open for discussion. Nevertheless, the results in this paper are of substantial importance. They demonstrate that OCT can be used to detect the different optical signatures associated with different demineralization models and track their dynamics. Further study of alternative models with different physiological significance could provide baseline measurements to which clinical OCT data could be compared and physically interpreted. AcknowledgmentsAbdi Aden was sponsored by GlaxoSmithKline (GSK) through the Biotechnology and Biological Sciences Research Council Industrial CASE award BB/K501190/1. The authors gratefully acknowledge Dr. Gary Burnett and Dr. Richard lynch from GSK for helpful discussion and providing the Bovine enamel specimens used in this work. ReferencesN. Garg and A. Garg, Textbook of Operative Dentistry, Jaypee Brothers Medical Publishers, New Delhi, India
(2010). Google Scholar
A. I. Ismail et al.,
“The International Caries Detection and Assessment System (ICDAS): an integrated system for measuring dental caries,”
Community Dent. Oral Epidemiol., 35
(3), 170
–178
(2007). http://dx.doi.org/10.1111/com.2007.35.issue-3 CDOEAP 0301-5661 Google Scholar
R. S. Jones and D. Fried,
“Remineralization of enamel caries can decrease optical reflectivity,”
J. Dent. Res., 85
(9), 804
–808
(2006). http://dx.doi.org/10.1177/154405910608500905 JDREAF 0022-0345 Google Scholar
G. H. Sperber and M. G. Buonocore,
“Effect of different acids on character of demineralization of enamel surfaces,”
J. Dent. Res., 42
(2), 707
–723
(1963). http://dx.doi.org/10.1177/00220345630420022001 JDREAF 0022-0345 Google Scholar
B. T. Amaechi, S. M. Higham and W. M. Edgar,
“Use of transverse microradiography to quantify mineral loss by erosion in bovine enamel,”
Caries Res., 32
(5), 351
–356
(1998). http://dx.doi.org/10.1159/000016471 CAREBK 0008-6568 Google Scholar
J. Arends, J. Schuthof and W. G. Jongebloed,
“Lesion depth and microhardness indentations on artificial white spot lesions,”
Caries Res., 14
(4), 190
–195
(1980). http://dx.doi.org/10.1159/000260453 CAREBK 0008-6568 Google Scholar
J. D. B. Featherstone et al.,
“Comparison of artificial caries-like lesions by quantitative microradiography and microhardness profiles,”
Caries Res., 17
(5), 385
–391
(1983). http://dx.doi.org/10.1159/000260692 CAREBK 0008-6568 Google Scholar
L. Holmen et al.,
“A scanning electron microscopic study of progressive stages of enamel caries in vivo,”
Caries Res., 19
(4), 355
–367
(1985). http://dx.doi.org/10.1159/000260867 CAREBK 0008-6568 Google Scholar
G. R. Davis, A. N. Z. Evershed and D. Mills,
“Quantitative high contrast x-ray microtomography for dental research,”
J. Dent., 41
(5), 475
–482
(2013). http://dx.doi.org/10.1016/j.jdent.2013.01.010 Google Scholar
G. R. Davis and F. S. L. Wong,
“X-ray microtomography of bones and teeth,”
Physiol. Meas., 17
(3), 121
–146
(1996). http://dx.doi.org/10.1088/0967-3334/17/3/001 PMEAE3 0967-3334 Google Scholar
A. M. A. Maia et al.,
“Evaluation of dental enamel caries assessment using quantitative light induced fluorescence and optical coherence tomography: enamel caries detection: QLF and OCT,”
J. Biophotonics, 9
(6), 596
–602
(2016). http://dx.doi.org/10.1002/jbio.v9.6 Google Scholar
H. Kang et al.,
“Nondestructive assessment of early tooth demineralization using cross-polarization optical coherence tomography,”
IEEE J. Sel. Top. Quantum Electron., 16
(4), 870
–876
(2010). http://dx.doi.org/10.1109/JSTQE.2009.2033610 IJSQEN 1077-260X Google Scholar
B. T. Amaechi et al.,
“Use of optical coherence tomography for assessment of dental caries: quantitative procedure,”
J. Oral Rehabil., 28
(12), 1092
–1093
(2001). http://dx.doi.org/10.1046/j.1365-2842.2001.00840.x JORHBY Google Scholar
Y. Shimada et al.,
“Noninvasive cross-sectional imaging of proximal caries using swept-source optical coherence tomography (SS-OCT) in vivo,”
J. Biophotonics, 7
(7), 506
–513
(2014). http://dx.doi.org/10.1002/jbio.201200210 Google Scholar
A. Baumgartner et al.,
“Polarization–sensitive optical coherence tomography of dental structures,”
Caries Res., 34
(1), 59
–69
(2000). http://dx.doi.org/10.1159/000016571 CAREBK 0008-6568 Google Scholar
D. Fried et al.,
“Imaging caries lesions and lesion progression with polarization sensitive optical coherence tomography,”
J. Biomed. Opt., 7
(4), 618
–627
(2002). http://dx.doi.org/10.1117/1.1509752 JBOPFO 1083-3668 Google Scholar
H. P. Chew et al.,
“Measuring initial enamel erosion with quantitative light-induced fluorescence and optical coherence tomography: an in vitro validation study,”
Caries Res., 48
(3), 254
–262
(2014). http://dx.doi.org/10.1159/000354411 CAREBK 0008-6568 Google Scholar
W. F. Cheong, S. A. Prahl and A. J. Welch,
“A review of the optical properties of biological tissues,”
IEEE J. Quantum Electron., 26
(12), 2166
–2185
(1990). http://dx.doi.org/10.1109/3.64354 Google Scholar
E. S. Papazoglou et al.,
“Changes in optical properties of tissue during acute wound healing in an animal model,”
J. Biomed. Opt., 13
(4), 044005
(2008). http://dx.doi.org/10.1117/1.2960952 JBOPFO 1083-3668 Google Scholar
L. Karlsson,
“Caries detection methods based on changes in optical properties between healthy and carious tissue,”
Int. J. Dent., 2010 1
–9
(2010). http://dx.doi.org/10.1155/2010/270729 Google Scholar
S. Anand et al.,
“Estimation of tissue optical properties between different grades and stages of urothelial carcinoma using diffuse reflectance spectroscopy,”
in Int. Conf. on BioPhotonics,
1
–3
(2015). http://dx.doi.org/10.1109/BioPhotonics.2015.7304015 Google Scholar
S. L. Jacques,
“Optical properties of biological tissues: a review,”
Phys. Med. Biol., 58
(11), R37
(2013). http://dx.doi.org/10.1088/0031-9155/58/11/R37 PHMBA7 0031-9155 Google Scholar
M. Almasian et al.,
“Validation of quantitative attenuation and backscattering coefficient measurements by optical coherence tomography in the concentration-dependent and multiple scattering regime,”
J. Biomed. Opt., 20
(12), 121314
(2015). http://dx.doi.org/10.1117/1.JBO.20.12.121314 JBOPFO 1083-3668 Google Scholar
D. Faber et al.,
“Quantitative measurement of attenuation coefficients of weakly scattering media using optical coherence tomography,”
Opt. Express, 12
(19), 4353
–4365
(2004). http://dx.doi.org/10.1364/OPEX.12.004353 OPEXFF 1094-4087 Google Scholar
D. Levitz et al.,
“Determination of optical scattering properties of highly-scattering media in optical coherence tomography images,”
Opt. Express, 12
(2), 249
–259
(2004). http://dx.doi.org/10.1364/OPEX.12.000249 OPEXFF 1094-4087 Google Scholar
V. M. Kodach et al.,
“Determination of the scattering anisotropy with optical coherence tomography,”
Opt. Express, 19
(7), 6131
–6140
(2011). http://dx.doi.org/10.1364/OE.19.006131 OPEXFF 1094-4087 Google Scholar
N. Choudhury and S. L. Jacques,
“Extracting scattering coefficient and anisotropy factor of tissue using optical coherence tomography,”
Proc. SPIE, 8221 822111
(2012). http://dx.doi.org/10.1117/12.907401 PSISDG 0277-786X Google Scholar
S. Prahl,
“Light transport in tissue,”
University of Texas Austin,
(1988). Google Scholar
B. Povazay et al.,
“Three-dimensional optical coherence tomography at 1050 nm versus 800 nm in retinal pathologies: enhanced performance and choroidal penetration in cataract patients,”
J. Biomed. Opt., 12
(4), 041211
(2007). http://dx.doi.org/10.1117/1.2773728 JBOPFO 1083-3668 Google Scholar
V. M. Kodach et al.,
“Quantitative comparison of the OCT imaging depth at 1300 nm and 1600 nm,”
Biomed. Opt. Express, 1
(1), 176
–185
(2010). http://dx.doi.org/10.1364/BOE.1.000176 BOEICL 2156-7085 Google Scholar
J. C. Elliott et al.,
“Determination of mineral concentration in dental enamel from x-ray attenuation measurements,”
Connect. Tissue Res., 38
(1–4), 61
–72
(1998). http://dx.doi.org/10.3109/03008209809017022 CVTRBC 0300-8207 Google Scholar
Y. Shimamura et al.,
“Influence of tooth-surface hydration conditions on optical coherence-tomography imaging,”
J. Dent., 39
(8), 572
–577
(2011). http://dx.doi.org/10.1016/j.jdent.2011.06.004 Google Scholar
C. L. Darling, G. D. Huynh and D. Fried,
“Light scattering properties of natural and artificially demineralized dental enamel at 1310 nm,”
J. Biomed. Opt., 11
(3), 034023
(2006). http://dx.doi.org/10.1117/1.2204603 JBOPFO 1083-3668 Google Scholar
D. Fried et al.,
“Nature of light scattering in dental enamel and dentin at visible and near-infrared wavelengths,”
Appl. Opt., 34
(7), 1278
–1285
(1995). http://dx.doi.org/10.1364/AO.34.001278 APOPAI 0003-6935 Google Scholar
D. Levitz et al.,
“Quantitative characterization of developing collagen gels using optical coherence tomography,”
J. Biomed. Opt., 15
(2), 026019
(2010). http://dx.doi.org/10.1117/1.3377961 JBOPFO 1083-3668 Google Scholar
J. M. Schmitt, A. Knüttel and R. F. Bonner,
“Measurement of optical properties of biological tissues by low-coherence reflectometry,”
Appl. Opt., 32
(30), 6032
–6042
(1993). http://dx.doi.org/10.1364/AO.32.006032 APOPAI 0003-6935 Google Scholar
F. J. van der Meer et al.,
“Localized measurement of optical attenuation coefficients of atherosclerotic plaque constituents by quantitative optical coherence tomography,”
IEEE Trans. Med. Imaging, 24
(10), 1369
–1376
(2005). http://dx.doi.org/10.1109/TMI.2005.854297 ITMID4 0278-0062 Google Scholar
G. van Soest et al.,
“Atherosclerotic tissue characterization in vivo by optical coherence tomography attenuation imaging,”
J. Biomed. Opt., 15
(1), 011105
(2010). http://dx.doi.org/10.1117/1.3280271 JBOPFO 1083-3668 Google Scholar
O. K. Adegun et al.,
“Quantitative analysis of optical coherence tomography and histopathology images of normal and dysplastic oral mucosal tissues,”
Lasers Med. Sci., 27
(4), 795
–804
(2011). http://dx.doi.org/10.1007/s10103-011-0975-1 Google Scholar
J.-W. Su et al.,
“Precancerous esophageal epithelia are associated with significantly increased scattering coefficients,”
Biomed. Opt. Express, 6
(10), 3795
–3805
(2015). http://dx.doi.org/10.1364/BOE.6.003795 BOEICL 2156-7085 Google Scholar
D. P. Popescu et al.,
“Assessment of early demineralization in teeth using the signal attenuation in optical coherence tomography images,”
J. Biomed. Opt., 13
(5), 054053
(2008). http://dx.doi.org/10.1117/1.2992129 JBOPFO 1083-3668 Google Scholar
M. M. Mandurah et al.,
“Monitoring remineralization of enamel subsurface lesions by optical coherence tomography,”
J. Biomed. Opt., 18
(4), 046006
(2013). http://dx.doi.org/10.1117/1.JBO.18.4.046006 JBOPFO 1083-3668 Google Scholar
I. Hariri et al.,
“Effects of structural orientation of enamel and dentine on light attenuation and local refractive index: an optical coherence tomography study,”
J. Dent., 40
(5), 387
–396
(2012). http://dx.doi.org/10.1016/j.jdent.2012.01.017 Google Scholar
R. A. McLaughlin et al.,
“Parametric imaging of cancer with optical coherence tomography,”
J. Biomed. Opt., 15
(4), 046029
(2010). http://dx.doi.org/10.1117/1.3479931 JBOPFO 1083-3668 Google Scholar
P. H. Tomlins et al.,
“Scattering attenuation microscopy of oral epithelial dysplasia,”
J. Biomed. Opt., 15 066003
(2010). http://dx.doi.org/10.1117/1.3505019 JBOPFO 1083-3668 Google Scholar
A. Zvyagin et al.,
“Refractive index tomography of turbid media by bifocal optical coherence refractometry,”
Opt. Express, 11 3503
–3517
(2003). http://dx.doi.org/10.1364/OE.11.003503 OPEXFF 1094-4087 Google Scholar
G. J. Tearney et al.,
“Determination of the refractive index of highly scattering human tissue by optical coherence tomography,”
Opt. Lett., 20
(21), 2258
–2260
(1995). http://dx.doi.org/10.1364/OL.20.002258 OPLEDP 0146-9592 Google Scholar
D. Segelstein,
“The complex refractive index of water,”
University of Missouri,
(1981). Google Scholar
Z. Meng et al.,
“Measurement of the refractive index of human teeth by optical coherence tomography,”
J. Biomed. Opt., 14
(3), 034010
(2009). http://dx.doi.org/10.1117/1.3130322 JBOPFO 1083-3668 Google Scholar
M. E. Barbour et al.,
“Human enamel dissolution in citric acid as a function of pH in the range —a nanoindentation study,”
Eur. J. Oral Sci., 111
(3), 258
–262
(2003). http://dx.doi.org/10.1034/j.1600-0722.2003.00039.x Google Scholar
J. A. Hughes et al.,
“Effects of pH and concentration of citric, malic and lactic acids on enamel, in vitro,”
J. Dent., 28
(2), 147
–152
(2000). http://dx.doi.org/10.1016/S0300-5712(99)00060-3 Google Scholar
A. Young and L. M. A. Tenuta,
“Initial erosion models,”
Caries Res., 45
(Suppl. 1), 33
–42
(2011). http://dx.doi.org/10.1159/000325943 CAREBK 0008-6568 Google Scholar
P. Anderson and J. C. Elliott,
“Subsurface demineralization in dental enamel and other permeable solids during acid dissolution,”
J. Dent. Res., 71
(8), 1473
–1481
(1992). http://dx.doi.org/10.1177/00220345920710080301 JDREAF 0022-0345 Google Scholar
K. H. Chan et al.,
“Methods for monitoring erosion using optical coherence tomography,”
Proc. SPIE, 8566 856606
(2013). http://dx.doi.org/10.1117/12.2011013 Google Scholar
J. M. ten Cate et al.,
“Effect of timing of fluoride treatment on enamel de- and remineralization in vitro: a pH-cycling study,”
Caries Res., 22
(1), 20
–26
(1988). http://dx.doi.org/10.1159/000261078 CAREBK 0008-6568 Google Scholar
J. J. M. Damen, M. J. Buijs and J. M. ten Cate,
“Fluoride-dependent formation of mineralized layers in bovine dentin during demineralization in vitro,”
Caries Res., 32
(6), 435
–440
(1998). http://dx.doi.org/10.1159/000016484 CAREBK 0008-6568 Google Scholar
S. E. Jabbarifar et al.,
“Effect of fluoridated dentifrices on surface microhardness of the enamel of deciduous teeth,”
Dent. Res. J., 8
(3), 113
–117
(2011). Google Scholar
A. M. Rollins and J. A. Izatt,
“Optimal interferometer designs for optical coherence tomography,”
Opt. Lett., 24 1484
–1486
(1999). http://dx.doi.org/10.1364/OL.24.001484 OPLEDP 0146-9592 Google Scholar
P. D. Woolliams et al.,
“Spatially deconvolved optical coherence tomography,”
Appl. Opt., 49
(11), 2014
–2021
(2010). http://dx.doi.org/10.1364/AO.49.002014 APOPAI 0003-6935 Google Scholar
P. D. Woolliams and P. H. Tomlins,
“Estimating the resolution of a commercial optical coherence tomography system with limited spatial sampling,”
Meas. Sci. Technol., 22 065502
(2011). http://dx.doi.org/10.1088/0957-0233/22/6/065502 MSTCEP 0957-0233 Google Scholar
A. C. Chan et al.,
“Attenuation of near-IR light through dentin at wavelengths from 1300–1650-nm,”
Proc. SPIE, 8929 89290M
(2014). http://dx.doi.org/10.1117/12.2045629 PSISDG 0277-786X Google Scholar
P. Anderson, M. Levinkind and J. C. Elliott,
“Scanning microradiographic studies of rates of in vitro demineralization in human and bovine dental enamel,”
Arch. Oral Biol., 43
(8), 649
–656
(1998). http://dx.doi.org/10.1016/S0003-9969(98)00052-1 AOBIAR 0003-9969 Google Scholar
H. C. Margolis et al.,
“Kinetics of enamel demineralization in vitro,”
J. Dent. Res., 78
(7), 1326
–1335
(1999). http://dx.doi.org/10.1177/00220345990780070701 JDREAF 0022-0345 Google Scholar
H. M. Theuns et al.,
“Effect of the pH of buffer solutions on artificial carious lesion formation in human tooth enamel,”
Caries Res., 18
(1), 7
–11
(1984). http://dx.doi.org/10.1159/000260740 CAREBK 0008-6568 Google Scholar
|