Prostate cancer (PCa) is a heterogeneous disease with multifocal origin. In current clinical care, the Gleason scoring system is the well-established diagnosis by microscopic evaluation of the tissue from trans-rectal ultrasound (TRUS) guided biopsies. Nevertheless, the sensitivity and specificity in detecting PCa can range from 40 to 50% for conventional TRUS B-mode imaging. Tissue elasticity is associated with the disease progression and elastography technique has recently shown promise in aiding PCa diagnosis. However, many cancer foci in the prostate gland has very small size less than 1 mm and those detected by medical elastography were larger than 2 mm. Hereby, we introduce optical coherence elastography (OCE) to quantify the prostate stiffness with high resolution in the magnitude of 10 µm. Following our feasibility study of 10 patients reported previously, we recruited 60 more patients undergoing 12-core TRUS guided biopsies for suspected PCa with a total of 720 biopsies. The stiffness of cancer tissue was approximately 57.63% higher than that of benign ones. Using histology as reference standard and cut-off threshold of 600kPa, the data analysis showed sensitivity and specificity of 89.6% and 99.8% respectively. The method also demonstrated potential in characterising different grades of PCa based on the change of tissue morphology and quantitative mechanical properties. In conclusion, quantitative OCE can be a reliable technique to identify PCa lesion and differentiate indolent from aggressive cancer.
By combining with the phase sensitive optical coherence tomography (PhS-OCT), vibration and surface acoustic wave (SAW) methods have been reported to provide elastography of skin tissue respectively. However, neither of these two methods can provide the elastography in full skin depth in current systems. This paper presents a feasibility study on an optical coherence elastography method which combines both vibration and SAW in order to give the quantitative mechanical properties of skin tissue with full depth range, including epidermis, dermis and subcutaneous fat. Experiments are carried out on layered tissue mimicking phantoms and invivo human forearm and palm skin. A ring actuator generates vibration while a line actuator were used to excited SAWs. A PhS-OCT system is employed to provide the ultrahigh sensitive measurement of the generated waves. The experimental results demonstrate that by the combination of vibration and SAW method the full skin bulk mechanical properties can be quantitatively measured and further the elastography can be obtained with a sensing depth from ~0mm to ~4mm. This method is promising to apply in clinics where the quantitative elasticity of localized skin diseases is needed to aid the diagnosis and treatment.
Generation of functional tissue in vitro through tissue engineering technique is a promising direction to repair and replace malfunctioned organ and tissue in the modern medicine for various diseases which could not been treated well by conventional therapy. Similar to the embryo development, the generation of tissue in vitro is a highly dynamic processing. Obtaining the feedback of the processing real time is highly demanded. In this study, a new methodology has been explored aiming to monitor the morphological and mechanical property alteration of bone tissue engineering constructs simultaneously. Optical coherence elastography (OCE) equipped with a LDS V201 permanent magnet shaker and a modulated acoustic radiation force (ARF) to provide a vibration signal, has been used for the real time and non-destructive monitoring. A phantom construct system has been used to optimize the measurement conditions in which agar hydrogel with concentration from 0, 0.75 to 2% with/without hydroxyappatite particles have been injected to 3D porous poly (lactic acid) scaffolds to simulate the collagenous extracellular matrix (ECM) and mineralized ECM. The structural and elastography images of the constructs have clearly demonstrated the linear relation with the increased mechanical property versus the increase of agar concentration within the pores of the scaffolds. The MG63 bone cells seeded in the scaffolds and cultured for 4 weeks have been monitored by the established protocol exhibiting the increased mechanical strength in the pore wall where the ECM or mineralized ECM was assumed to be formed in comparison to empty pores. This study confirms that OCE-ARF could become a valuable tool in regenerative medicine to assess the biological events during in vitro culture and conditioning.
Objectives. Prostate cancer is the most frequently diagnosed malignancy in men. Digital rectal examination (DRE) - a known clinical tool based on alteration in the mechanical properties of tissues due to cancer has traditionally been used for screening prostate cancer. Essentially, DRE estimates relative stiffness of cancerous and normal prostate tissue. Optical coherence elastography (OCE) are new optical imaging techniques capable of providing cross-sectional imaging of tissue microstructure as well as elastogram in vivo and in real time. In this preliminary study, OCE was used in the setting of the human prostate biopsies ex vivo, and the images acquired were compared with those obtained using standard histopathologic methods. Methods. 120 prostate biopsies were obtained by TRUS guided needle biopsy procedures from 9 patients with clinically suspected cancer of the prostate. The biopsies were approximately 0.8mm in diameter and 12mm in length, and prepared in Formalin solution. Quantitative assessment of biopsy samples using OCE was obtained in kilopascals (kPa) before histopathologic evaluation. The results obtained from OCE and standard histopathologic evaluation were compared provided the cross-validation. Sensitivity, specificity, and positive and negative predictive values were calculated for OCE (histopathology was a reference standard). Results. OCE could provide quantitative elasticity properties of prostate biopsies within benign prostate tissue, prostatic intraepithelial neoplasia, atypical hyperplasia and malignant prostate cancer. Data analysed showed that the sensitivity and specificity of OCE for PCa detection were 1 and 0.91, respectively. PCa had significantly higher stiffness values compared to benign tissues, with a trend of increasing in stiffness with increasing of malignancy. Conclusions. Using OCE, microscopic resolution elastogram is promising in diagnosis of human prostatic diseases. Further studies using this technique to improve the detection and staging of malignant cancer of the prostate are ongoing.
Damage of collagen fibers in tendons is often directly related to changes in a tendon’s mechanical properties. Direct quantitative elasticity measurement of tendons will provide important information in tendon dysfunction diagnosis and treatment assessment. A feasibility study of quantifying the mechanical properties of a degenerated tendon model by a nondestructive imaging modality, which combines optical coherence elastography and acoustic radiation force (ARF) method, is presented. The degenerated tendon model was produced by the partial degradation of chicken tendons through incubation with collagenase at different concentrations and incubation times. A 30-kHz longitudinal ultrasound transducer was used to provide an ARF signal, which was detected by an ultra-high sensitive phase sensitive optical coherence tomography (PhS-OCT) system. The experimental results demonstrate that the combination of ARF method and PhS-OCT can measure the elasticity of tendon quantitatively. The corresponding changes in tendon elasticity due to the application of collagenase have been revealed by this new imaging modality. This method can potentially be used in the assessment of tissue engineering products and in the diagnosis and treatment progression of tendon diseases.
The combined use of surface acoustic wave (SAW) and phase-sensitive optical coherence tomography (PhS-OCT) is useful to evaluate the elasticity of layered biological tissues, such as normal skin. However, the pathological tissue is often originated locally, leading to the alternation of mechanical properties along both axial and lateral directions. We present a feasibility study on whether the SAW technique is sensitive to detect the alternation of mechanical property along the lateral direction within tissue, which is important for clinical utility of this technique to localize diseased tissue. Experiments are carried out on purposely designed tissue phantoms and ex vivo chicken breast samples, simulating the localized change of elasticity. A PhS-OCT system is employed not only to provide the ultra-high sensitive measurement of the generated surface waves on the tissue surface, but also to provide the real time imaging of the tissue to assist the elasticity evaluation of the heterogeneous tissue. The experimental results demonstrate that with PhS-OCT used as a pressure sensor, the SAW is highly sensitive to the elasticity change of the specimen in both vertical and lateral directions with a sensing depth of ∼ 5 mm with our current system setup, thus promising its useful clinical applications where the quantitative elasticity of localized skin diseases is needed to aid in diagnosis and treatment.
Several imaging modalities such as optical coherence tomography, photothermal, photoacoustic and magnetic resonance imaging, are sensitive to different physical properties (i.e. scattering, absorption and magnetic) that can provide contrast within biological tissues. Usually exogenous agents are designed with specific properties to provide contrast for these imaging methods. In nano-biotechnology there is a need to combine several of these properties into a single contrast agent. This multifunctional contrast agent can then be used by various imaging techniques simultaneously or can be used to develop new imaging modalities. We reported and characterized a multifunctional nanoparticle, made from gold nanoshells, which exhibits scattering, photothermal, photoacoustic, and magnetic properties.
The concentration of photothermal (light-to-heat converters) compounds as a function of depth is determined in solid
agar gel phantoms. The system contains an 808nm pump laser, which excites the photothermal compound, and a phase
sensitive spectral domain optical coherence tomography system, which detects the changes in the optical pathlength of
the sample induced by the temperature increase. The derivation of the model is described, and its parameters are
empirically determined. The concentration of photothermal compounds are observed from double layer agar gel
phantoms.
This paper presents the combination of phase sensitive optical coherence tomography (PhS-OCT) imaging system and
surface wave method to achieve quantitative evaluation and elastography of the mechanical properties of in vivo human
skin. PhS-OCT measures the surface acoustic waves (SAWs) generated by impulse stimulation from a home-made
shaker, and provide the B-frame images for the sample. The surface wave phase velocity dispersion curves were
calculated, from which the elasticity of different skin layers were determined. The combination of phase velocities from
adjacent two locations generates a quantitative elastography of sample. The experimental results agree well with
theoretical expectations and may offer potential use in clinical situations.
A model that describes the concentration of photothermal (light-to-heat converters) compounds as a function of depth in a turbid medium is developed. The system consists of a pump laser (808 nm modulated at 400 Hz), which heats a photothermal compound, and a phase sensitive spectral domain optical coherence tomography system, which detects the changes in the optical path length of the sample induced by the temperature increase. The model is theoretically derived and the coefficients are empirically determined using solid homogeneous gel phantoms. The model is validated by reconstructing the concentration of a photothermal compound in thick single and double layer solid phantoms.
We propose a useful method to boost the imaging speed for spectral domain optical coherence tomography (SDOCT) by multiplying a number of high-speed spectrometers used in the system with selective precise control of data-recording and data-reading phases for spectral cameras employed in each spectrometer. To demonstrate the proposed method, we use two spectrometers built in a 1310 nm-band SDOCT system, each equipped with a high-speed InGaAs line-scan camera capable of 92-kHz line-scan rate, to achieve an unprecedented imaging speed at 184,000 lines/s. We validate the multiplied imaging speed by measuring Doppler-induced phase shift in the spectrograms using a flow phantom.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.