Line-edge roughness (LER) is often measured from top-down critical dimension scanning electron microscope (CD-SEM) images. The true three-dimensional roughness profile of the sidewall is typically ignored in such analyses.

We study the response of a CD-SEM to sidewall roughness (SWR) by simulation. We generate random rough lines and spaces, where the SWR is modelled by a known power spectral density. We then obtain corresponding CD-SEM images using a Monte Carlo electron scattering simulator.

We find the measured LER from these images, and compare it to the known input roughness. We find that, for isolated lines, the SEM measures the outermost extrusion of the rough sidewall. The result is that the measured LER is up to a factor 2 less than the true on-wafer roughness. The effect can be accurately modelled by making a top-down projection of the rough edge. Our model for isolated lines works fairly well for a dense grating of lines and spaces, as long as the trench width exceeds the line height.
Conference Presentation
© (2020) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
L. van Kessel, T. Huisman, and C. W. Hagen "Understanding the influence of 3D sidewall roughness on observed line-edge roughness in scanning electron microscopy images", Proc. SPIE 11325, Metrology, Inspection, and Process Control for Microlithography XXXIV, 113250Z (20 March 2020); https://doi.org/10.1117/12.2550240
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Scanning electron microscopy

Line edge roughness

Monte Carlo methods

3D modeling

Scattering

Electron beams

Metrology

Back to Top